Mira J95A Скачать руководство пользователя страница 28

28

Guarantee

Your  product  has  the  benefit  of  our  manufacturer’s 

guarantee which starts from the date of purchase.

To activate this guarantee, please return your completed 

registration  card,  visit  our  website  or  free  phone  0800 

0731248 within 30 days of purchase (UK only).

Within  the  guarantee  period  we  will  resolve  defects  in 

materials or workmanship, free of charge, by repairing or 

replacing parts or product as we may choose.

This guarantee is in addition to your statutory rights 

and is subject to the following conditions:

  ●  The guarantee applies solely to the original installation  

    under normal use and to the original purchaser only.

    The  product  must  be  installed  and  maintained  in 

    accordance  with  the  instructions  given  in  this  user 

    guide.

  ●  Servicing  must  only  be  undertaken  by  us  or  our   

    appointed  representative. 

Note!

  if  a  service  visit   

    is  required  the  product  must  be  fully  installed  and   

    connected to services.

  ●  Repair under this guarantee does not extend the original

    expiry date. The guarantee on any replacement parts  

    or product ends at the original expiry date.

  ●  For  shower  fi ttings  or  consumable  items  we  reserve  

    the right to supply replacement parts only.

The guarantee does not cover:

  ●  Call  out  charges  for  non  product  faults  (such  as 

damage or performance issues arising from incorrect 

installation, improper use, lack of maintenance, build up 

of limescale, frost damage, corrosion, system debris or 

blocked fi lters) or where no fault has been found with 

the product.

  ●  Water or electrical supply, waste and isolation issues.

  ●  Compensation  for  loss  of  use  of  the  product  or 

consequential loss of any kind.

  ●  Damage or defects caused if the product is repaired 

or  modifi ed  by  persons  not  authorised  by  us  or  our 

appointed representative.

  ●  Routine maintenance or replacement parts to comply 

with the requirements of the TMV 2 or TMV 3 healthcare 

schemes.

  ●  Accidental or wilful damage.

  ●  Products purchased ex-showroom display.

What to do if something goes wrong

If your product does not function correctly when you fi rst 

use  it,  contact  your  installer  to  check  that  it  is  installed 

and commissioned in accordance with the instructions in 

this manual.

If this does not resolve the issue, contact our Customer 

Services Team  who  will  offer  you  or  your  installer  help 

and advice.

If you experience problems, check in this manual to see if 

simple home maintenance is required. If you require further 

assistance call our Customer Services Team.

Extended Guarantees

A selection of protection plans are available that 

enable you to cover repair bills for the life of your policy 

(excludes Eire). Ring 01922 471763 for more details.

Helpdesk Service

Our Customer Services Team is comprehensively trained 

and can offer help and advice, spare parts, accessories or 

a service visit.

We  will  need  you  to  have  your  model  name  or  number, 

power rating (if applicable) and date of purchase. As part of 

our quality and training programme calls may be recorded 

or monitored.

Mira Showers Website 

(www.mirashowers.co.uk)

From  our  website  you  can  register  your  guarantee, 

download additional user guides, diagnose faults, purchase 

our full range of accessories and popular spares, refer to 

our FAQ’s and request a service visit.

Spares and Accessories

We  maintain  extensive  stocks  of  genuine  spares  and 

accessories  and  aim  to  provide  support  throughout  the 

product’s expected life.

Payment  can  be  made  by  phone  at  time  of  order  using 

most major Credit or Debit cards and we aim to despatch 

orders within 2 working days. Items purchased from us are 

guaranteed for 12 months from date of purchase. For safety 

reasons spares exposed to mains voltages should only be 

fi tted by competent persons.

Returns

 – items can be returned within one month of date 

of purchase, providing that they are in good condition and 

the packaging is unopened. If you wish to return any items 

please notify us in writing within seven days of receipt.

Service / Repairs

Our nationwide team of Service Technicians can carry out 

service or repair work to your product within the guarantee 

period and beyond. You have the assurance of a fully trained 

Technician, genuine spare parts and a 12 month guarantee 

on any chargeable work done.

Payment should be made directly to the Service Technician 

who will accept most major Credit or Debit cards.

To Contact Us

UK

Telephone: 0844 571 5000

E-mail - Visit 

www.mirashowers.co.uk/contactus

Fax: 01242 282595

By Post: Mira Customer Services Dept, Cromwell Road, 

Cheltenham, Gloucestershire, GL52 5EP

Eire

Telephone: 01 459 1344

E-mail: [email protected]

Fax: Dublin 01 459 2329

By Post: Modern Plant Ltd (Dublin),

Otter House, Naas Road, Clondalkin, Dublin 22

Mira is a registered trade mark of 

Kohler Mira Limited.

The company reserves the right to alter 

product specifi cations without notice.

FM 14648

1060737-W2-G (1563) (J95A/B/C/V/W)

© Kohler Mira Limited, January 2012

CUSTOMER SERVICE

Содержание J95A

Страница 1: ...1 These instructions must be left with the user Installation Guide Mira Sport 7 5 9 0 9 8 kW...

Страница 2: ...Patents and Design Registration 3 Important Safety Information 4 Pack Contents Checklist 5 Wiring Diagram 6 Specifications 7 Plumbing 7 Electrical 7 Dimensions 7 Installation Requirements 8 Plumbing...

Страница 3: ...s guide Product Model Number Colour Mira Sport 7 5 J95A White Chrome Mira Sport 9 0 J95B J95V White Chrome Chrome Mira Sport 9 8 J95C J95W White Chrome Chrome Guarantee For domestic installations Mira...

Страница 4: ...bility that the water in the shower is frozen 6 DO NOT switch the shower on if water starts leaking from the shower case Isolate the electrical supply to the shower immediately 7 DO NOT connect the ou...

Страница 5: ...f with the part names and to confirm that the parts are included q 3 x Wall Plugs q 1 x Compression Nut q 3 x Fixing Screws q 2 x Case Inserts q 1 x Olive q 1 x Mira Sport 7 5 9 0 or 9 8 Documentation...

Страница 6: ...BLACK BLUE BLUE GREEN GREEN BLACK RED RED RED Thermal Cutout Dual Disc L Solenoid Valve Pressure Power Selector Switch Low Flow Neon Power On Neon N E Tank Connection Inlet Connector Internal Wiring D...

Страница 7: ...ort 9 0 Sport 9 8 Nominal Power at 230 V ac 6 9 kW 8 3 kW 9 0 kW Nominal Power at 240 V ac 7 5 kW 9 0 kW 9 8 kW Recommended MCB Rating 40 A 40 A 45 A Maximum Supply Cable Size 16 mm Recommended RCD Ra...

Страница 8: ...and is fitted with a pressure relief valve It must be positioned over a water catchment area with the controls at a convenient height for the user 6 The shower must be fitted to a waterproof flat and...

Страница 9: ...itable Zone of Backflow Risk 30 mm Minimum Toilet or Bidet FC5 Hand Basin FC3 Bath or Shower Tray FC3 Electric Shower 25 mm Minimum 25 mm Minimum 15 A full bore non restrictive servicing valve must be...

Страница 10: ...ains system A separate supply must be provided from the consumer unit to the shower 5 DO NOT supply any other electrical equipment including extractor fans or pumps via this product 6 This shower must...

Страница 11: ...Sport Attention Installer Caution Do not drill into buried cables or pipes Drill and plug the three holes using template R e m o v e c o v e r a n d determine supply pipe position For back inlet use s...

Страница 12: ...wires are clear of all mounting holes Refit the Service Tunnel and Cover Make sure they fit correctly Do not overtighten screws Do not use alternative screws to secure the Cover This can cause intern...

Страница 13: ...g COMMISSIONING Electrical supply is turned off at the mains Turn control to full cold Turn water supply fully on Check for water leaks Set control to LOW Switch on electrical supply Push START button...

Страница 14: ...l affect the tone This is quite normal in use Set control to HIGH _ The temperature will rise further Adjust temperature as required Flow rate will adjust automatically Press STOP and isolate power Th...

Страница 15: ...CTIONS The warmer the shower the lower the flow rate and vice versa _ COLD _ _ Hot water is produced by passing cold water through a heating tank The shower has three heater settings How Your Electric...

Страница 16: ...wer select HIGH Adjust the temperature as required The flow rate will adjust automatically The Effect of Seasonal Changes The Effect of Other Water Devices Showering temperature will stabilize to with...

Страница 17: ...burn or skin conditions can increase your WARNING THIS SHOWER CAN DELIVER SCALDING TEMPERATURES IF NOT OPERATED INSTALLED OR MAINTAINED IN ACCORDANCE WITH THE INSTRUCTIONS WARNINGSAND CAUTIONS CONTAIN...

Страница 18: ...un for a few seconds before stopping _ Switch on electrical supply Press START button Set to desired position Allow 10 15 seconds for any temperature adjustments to reach the handset _ Check water tem...

Страница 19: ...t double pole switch Fuse blown or MCB RCD tripped indicating possible electrical fault Switch on electrical s up p l y vi a the pullcord or wall mounted switch Renew the fuse or reset the MCB R C D I...

Страница 20: ...hut off Flow Valve faulty Min static pressure to ensure shut off and prevent dripping is 20 kPa 0 2 bar N o t e I f o t h e r appliances are operating static p r e s s u r e m a y drop below 20 k P a...

Страница 21: ...k excessively scaled Tu r n o ff o t h e r appliances whilst shower is in use Remove and clean Check case inserts are cut and fitted correctly Check services electrical or plumbing are not interferin...

Страница 22: ...not turn off ON ON OFF ON Any Any Flowvalve solenoid or Start Stop switch faulty Supply pressure b e l o w 2 0 k P a 0 2 bar R e p l a c e a s necessary Contact local water company Check mains water...

Страница 23: ...em of water Unscrew the hose from the showerhead and the shower outlet Inspect the hose Cleaning Many household cleaners contain abrasives and chemical substances and should not be used for cleaning p...

Страница 24: ...sary Refit in reverse order making sure the Filter is screwed fully home Do not overtighten Make sure plumbing connections are sealed before restoring electricity supply Refit the cover making sure it...

Страница 25: ...embly 1563 513 Screw Pack components identified A 1563 514 Low Flow Neon Assembly 1563 515 Power On Neon Assembly 1563 516 Outlet Connector 1563 517 Service Tunnel 1563 518 Component Pack components i...

Страница 26: ...58 1563 517 1563 516 A A A B B B B B B B B B 1563 507 1563 519 1563 509 872 28 872 01 Important Push fit connectors must be assembled back to back onto terminals of micro switches A minimum air gap o...

Страница 27: ...002 Stylish slim line and robust shower seat for use in or outside of the shower area Folds up when not in use Maximum User Weight 150 kg 23 5 stone Note Must be installed onto a solid wall Logic Sho...

Страница 28: ...ee if simple home maintenance is required If you require further assistance call our Customer Services Team Extended Guarantees A selection of protection plans are available that enable you to cover r...

Отзывы: