1

1062243-W2-N

These instructions must be left with the user

Mira Azora
9.8 kW

Installation and User Guide

For SPARES, 

ADVICE or REPAIRS 

please call us free 

on 0800 001 4040 

(UK only)

Содержание Azora

Страница 1: ...1 1062243 W2 N These instructions must be left with the user Mira Azora 9 8 kW Installation and User Guide For SPARES ADVICE or REPAIRS please call us free on 0800 001 4040 UK only...

Страница 2: ...Children shall not be allowed to play with the shower 3 Cleaning and user maintenance shall not be made by children without supervision 4 The appliance is not to be used by persons including children...

Страница 3: ...t mode point handset away from body and make sure that the water temperature has stabilised before continuing to shower 16 Use caution when altering the water temperature always check the temperature...

Страница 4: ...d for a long period of time If the product or pipework is at risk of freezing during this period they should also be drained of water 26 If the shower is dismantled during installation or servicing th...

Страница 5: ...1 x Olive 1 x Compression Nut 1 x Mira Azora Documentation 1 x Installation and User Guide 1 x Installation Template 1 x Guarantee and Registration Document BROWN BROWN BROWN BROWN RED RED RED BROWN B...

Страница 6: ...ing turned on or off or a toilet being flushed An individual light indicates START STOP The Mira Azora comes complete with a set of Mira Energise Shower Fittings A 9 8 kW 240 V AC 9 0 kW 230 V AC heat...

Страница 7: ...ith 3 mm contact separation Appliance Sealing Rating IP X4 Suitable for installation in Zone 1 MaximumAmbient Temperature 30 C Minimum Ambient Temperature 2 C Plumbing Variant Azora 9 8 Minimum Dynami...

Страница 8: ...iod of one year from the date of purchase For terms and conditions refer to section Customer Services Guarantee The Mira Azora shower complies with the following European directives 2006 95 EC Low Vol...

Страница 9: ...ace 7 DO NOT fit the shower to the wall and tile up to the case 8 DO NOT seal the gap between the shower and the wall surface 9 The showerhead should be positioned so that it discharges down the centr...

Страница 10: ...installation until the plumbing has been completed and checked for leaks Hose retaining ring fitted and shower fittings fixed at a suitable height preventing dirty water backflow Note There will be o...

Страница 11: ...consumer unit to the shower 5 DO NOT supply any other electrical equipment including extractor fans or pumps via this product 6 This shower must be provided with means for local disconnection that is...

Страница 12: ...off at the mains and the appropriate circuit fuse removed if applicable Note An installation template is supplied to help you install the shower Remove the three cover retaining screws the cover and...

Страница 13: ...holes Make sure that the position of these holes do not come in line with any buried cables or pipework Make sure that sufficient electrical supply cable is available for connection to the terminal b...

Страница 14: ...ighten screws Caution Handle the glass cover assembly with care Do not use alternative screws to secure the cover This can cause internal damage to the appliance Do not seal around the back of applian...

Страница 15: ...15 1062243 W2 N Cold Water Supply Pipe Bottom Entry Fixing Screw Holes For Cover Retaining Screws Terminal Block Inlet Connector Assembly Heater Tank...

Страница 16: ...ease read through the section User Instructions before continuing Turn control to full cold Turn the water supply fully on Check for water leaks Set control to I Switch on electrical supply Press the...

Страница 17: ...use Turn control to full cold The temperature will rise slightly Set control to II 0 10 Secs 12 11 10 The temperature will rise further Adjust temperature as required Flow rate will adjust automatical...

Страница 18: ...s How Your Electric Shower Works The warmer the shower the lower the flow rate and vice versa Heated water is produced by adjusting the flow of cold water passed through a heater tank The shower has t...

Страница 19: ...ature across the range from hot to cold whilst also dealing with fluctuations in electrical and water supplies As a result there is a temperature limit the shower cannot go beyond For safety this temp...

Страница 20: ...set after the shower has been turned off This may drain over a few minutes Press the Start Stop button 2 Switch on electrical supply 1 Set to desired position 3 Residual water may drain over a few min...

Страница 21: ...upply conditions remain within the required operating parameters refer to section Specifications For a cold shower select I For a summer warm shower select II For a winter warm shower select III Durin...

Страница 22: ...k a n d o r appliance isolating valve is fully turned on Temperature dial or Heater setting too high Turn the heater selector knob to setting II or turn the temperature control until a cooler tempera...

Страница 23: ...of 0 7 bar Note If other appliances are operating pressure may drop below 0 7 bar Other outlets e g toilet garden hose washing machine etc drawing water while the shower is being used Turn off other...

Страница 24: ...and replace parts as necessary Water will not turn off ON ANY Inlet valve solenoid or start stop switch faulty Replace as necessary Supply pressure below 0 2 bar Contact local water company Check mai...

Страница 25: ...drain them of water Unscrew the hose from the showerhead and the shower outlet Inspect the hose Cleaning Many household cleaners contain abrasives and chemical substances and should not be used for c...

Страница 26: ...the electrical supply is turned off at the mains and that the water supply is fully turned off Remove the three screws and the cover Inlet Filter Cleaning Renewing Read the section Important Safety I...

Страница 27: ...Start Stop LED Assembly 1634 026 Screw Pack components identified A 1623 009 Cover Assembly Frosted Glass 1634 118 Cover Assembly Blue Glass 1634 119 Cover Assembly Grape Glass 1634 120 Cover Assembl...

Страница 28: ...indirect loss of any kind Damage or defects caused if the product is repaired or modified by persons not authorised by us or our appointed representative Routine maintenance or replacement parts to r...