Mira Alero Скачать руководство пользователя страница 3

3

IMPORTANT SAFETY INFORMATION

WARNING - This shower can deliver scalding temperatures if not operated, 

installed or maintained in accordance with the instructions, warnings and 

cautions contained in this guide and on or inside the appliance. 
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY:

1.  Installation of this shower must be carried out in accordance with these 

instructions by qualified, competent personnel. 

2.  Isolate the electrical and water supplies before commencing installation. The 

electricity must be isolated at the consumer unit and the appropriate circuit 

fuse removed, if applicable. Mains connections are exposed when the cover 

is removed.

3. 

DO NOT

 install the shower in areas with high humidity and temperature  

(i.e. steam rooms and saunas).

4. 

DO NOT

 install the shower where it may be exposed to freezing conditions. 

Ensure that any pipework that could become frozen is properly insulated.

5. 

DO NOT 

switch the shower on if there is a possibility that the water in the 

shower is frozen. 

6. 

DO NOT

 switch the shower on if water starts leaking from the shower case. 

Isolate the electrical supply to the shower immediately.

7. 

DO NOT

 connect the outlet of the shower to any tap, control valve, trigger 

handset or showerhead other than those specified for use with this shower - 

scalding water temperatures and product damage will occur. Only Kohler Mira 

recommended accessories should be used.

8.  The water supplies to this product must be isolated if the product is not to be 

used for a long period of time. If the product or pipework is at risk of freezing 

during this period they should also be drained of water.

9. 

DO NOT

 perform any unspecified modifications to the shower or it’s accessories. 

When servicing only use Genuine Kohler Mira replacement parts.

10.  If the shower is dismantled during installation or servicing then upon completion 

the product must be inspected to ensure all electrical connections are tight and 

that there are no leaks.

11.  Read all installation instructions before installing this shower.
12.  Upon completion of the installation, make sure that the user is familiar with the 

operation of the shower, and leave this guide with the owner.

Содержание Alero

Страница 1: ...1 These instructions must be left with the user Installation and User Guide Mira Alero 9 8 kW For SPARES ADVICE or REPAIRS Please call us on 0844 571 5000 UK Only...

Страница 2: ...e adjustable spray handset with four different spray actions start soothe force and eco Supplied complete with flexible hose clamp bracket assembly slide bar supports hose retaining ring and soap dish...

Страница 3: ...shower is frozen 6 DO NOT switch the shower on if water starts leaking from the shower case Isolate the electrical supply to the shower immediately 7 DO NOT connect the outlet of the shower to any tap...

Страница 4: ...ate boxes to familiarise yourself with the part names and to confirm that the parts are included 1 x Olive 1 x Compression Nut 1 x Mira Alero Documentation 1 x Installation and User Guide 1 x Installa...

Страница 5: ...N BROWN RED RED RED BROWN BROWN GREEN BLUE BLUE BLACK BLACK BLACK GREEN Thermal Cutout Disc Tank Connection Load Inlet Connector Pressure Power Selector Switch Solenoid Valve Start Stop L E D START ST...

Страница 6: ...rical Variant Alero 9 8 Nominal Power at 230 V ac 9 0 kW Nominal Power at 240 V ac 9 8 kW Recommended MCB Rating 45 A Maximum Supply Cable Size 16 mm Recommended RCD Rating 30 mA tripping current Reco...

Страница 7: ...on within the shower area and is fitted with a pressure relief valve It must be positioned over a water catchment area with the controls at a convenient height for the user 6 The shower must be fitted...

Страница 8: ...itable Zone of Backflow Risk 30 mm Minimum Toilet or Bidet FC5 Hand Basin FC3 Bath or Shower Tray FC3 Electric Shower 25 mm Minimum 25 mm Minimum 15 A full bore non restrictive servicing valve must be...

Страница 9: ...ins system A separate supply must be provided from the consumer unit to the shower 5 DO NOT supply any other electrical equipment including extractor fans or pumps via this product 6 This shower must...

Страница 10: ...er wall structures such as panels alternative fixings may be required A minimum of 3 fixing screws should be used Remove the three cover retaining screws and the cover Caution Handle the glass cover a...

Страница 11: ...s Ensure the position of these holes do not come in line with any buried cables or pipework Make sure that sufficient electrical supply cable is available for connection to the terminal block Drill an...

Страница 12: ...ocated Do not overtighten screws Caution Handle the glass cover assembly with care Do not use alternative screws to secure the cover This can cause internal damage to the appliance Do not seal around...

Страница 13: ...13 Cold Water Supply Pipe Bottom Entry Fixing Screw Holes For Cover Retaining Screws Terminal Block Inlet Connector Assembly Heater Tank...

Страница 14: ...l temperature Turn the control slowly Temperature remains cool and flow is reduced Electrical supply is turned off at the mains 0 5 Secs 1 4 3 2 6 5 9 8 7 Before carrying out the commissioning procedu...

Страница 15: ...automatically The shower will purge water from its tank for a few seconds Residual water may drain over a few minutes Set control to III 5 10 Secs 0 5 Secs 13 15 14 16 Press STOP 18 19 Note A slight...

Страница 16: ...the lower the flow rate and vice versa Heated water is produced by adjusting the flow of cold water passed through a heater tank The shower has three heater settings USER INSTRUCTIONS How Your Electri...

Страница 17: ...cross the range from hot to cold whilst also dealing with fluctuations in electrical and water supplies As a result there is a temperature limit the shower cannot go beyond For safety this temperature...

Страница 18: ...this guide for details 9 The shower hose must be checked regularly and replaced if damaged refer to the user maintenance section towards the rear of this guide for details 10 DO NOT store bathroom ite...

Страница 19: ...ments to reach the handset 6 Press STOP button Shower will continue to run for a few seconds before stopping 7 Isolate power _ _ Note At the end of every shower make sure that the shower head points i...

Страница 20: ...uired operating parameters refer to section Specifications For a cold shower select I For a summer warm shower select II For a winter warm shower select III During extremes of mains water supply tempe...

Страница 21: ...d o r appliance isolating valve is fully turned on Temperature dial or Heater setting too high Turn the heater selector knob to setting II or turn the temperature control until a cooler temperature i...

Страница 22: ...7 bar Note If other appliances are operating pressure may drop below 0 7 bar Other outlets e g toilet garden hose washing machine etc drawing water while the shower is being used Turn off other applia...

Страница 23: ...place parts as necessary Water will not turn off ON ANY Inlet valve solenoid or start stop switch faulty Replace as necessary Supply pressure below 0 2 bar Contact local water company Check mains wate...

Страница 24: ...f water Unscrew the hose from the showerhead and the shower outlet Inspect the hose Cleaning Many household cleaners contain abrasives and chemical substances and should not be used for cleaning plate...

Страница 25: ...y Refit in reverse order making sure the Filter is screwed fully home Do not overtighten Make sure plumbing connections are sealed before restoring electricity supply Refit the cover making sure it is...

Страница 26: ...d ACCESSORIES Shower Seat White 2 1536 128 White Chrome 2 1536 129 For use in or out of the showering area Note Must be installed onto a solid wall Shower seat folds up when not in use Double Outlet C...

Страница 27: ...062 416 38 416 41 416 48 416 51 872 01 872 28 1563 507 1563 539 A A A A A A A A A A 1563 534 1563 519 1634 052 1634 102 1634 103 1563 533 1563 537 1563 538 B B B B B 1634 015 Mira Alero Spare Parts D...

Страница 28: ...ot work correctly refer to this manual for fault diagnosis and check that it is installed and commissioned in accordance with our instructions If this does not resolve the issue contact us for help an...

Отзывы: