Mira Alero Скачать руководство пользователя страница 24

24

USER MAINTENANCE

There are no user serviceable 

parts inside the shower. Only 

qualified, competent personnel 

should remove the front cover,  

mains  connections  are  exposed 

when the cover is removed.
Switch the shower off at the isolator 

switch before performing any user 

maintenance or before cleaning 

the shower.

DO NOT

 allow young children 

to perform user maintenance 

including cleaning of the shower.

Use your thumb or a 

soft cloth to wipe any 

limescale from the 

soft nozzles

DO NOT

 use the showerhead to 

clean the shower.
If the shower is not to be used for 

a long period, the electrical supply 

and water supply to the shower 

should be isolated. If the shower 

or  pipework  is  at  risk  of  freezing 

during this period a qualified, 

competent person should drain 

them of water. 

Unscrew the hose from 

the showerhead and 

the shower outlet.

Inspect the hose.

Cleaning

Many household cleaners contain abrasives and chemical substances, and should 

not be used for cleaning plated or plastic parts or fittings. These finishes should 

be cleaned with a mild washing up detergent or soap solution, and then wiped dry 

using a soft cloth.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY:

De-scaling the Showerhead

Important! 

Keeping the showerhead 

clean and free from limescale will ensure 

that your shower and showerhead 

continue to perform to their maximum. 

A blocked showerhead can restrict the 

flow rate and may cause damage to 

your shower

Inspecting the hose.
Important! 

The shower hose should 

be inspected periodically for damage 

or internal collapse, internal collapse 

can restrict the flow rate from the 

showerhead and may cause damage to 

the shower. Remove the shower hose 

from the shower, inspect and replace the 

hose if necessary.

Содержание Alero

Страница 1: ...1 These instructions must be left with the user Installation and User Guide Mira Alero 9 8 kW For SPARES ADVICE or REPAIRS Please call us on 0844 571 5000 UK Only...

Страница 2: ...e adjustable spray handset with four different spray actions start soothe force and eco Supplied complete with flexible hose clamp bracket assembly slide bar supports hose retaining ring and soap dish...

Страница 3: ...shower is frozen 6 DO NOT switch the shower on if water starts leaking from the shower case Isolate the electrical supply to the shower immediately 7 DO NOT connect the outlet of the shower to any tap...

Страница 4: ...ate boxes to familiarise yourself with the part names and to confirm that the parts are included 1 x Olive 1 x Compression Nut 1 x Mira Alero Documentation 1 x Installation and User Guide 1 x Installa...

Страница 5: ...N BROWN RED RED RED BROWN BROWN GREEN BLUE BLUE BLACK BLACK BLACK GREEN Thermal Cutout Disc Tank Connection Load Inlet Connector Pressure Power Selector Switch Solenoid Valve Start Stop L E D START ST...

Страница 6: ...rical Variant Alero 9 8 Nominal Power at 230 V ac 9 0 kW Nominal Power at 240 V ac 9 8 kW Recommended MCB Rating 45 A Maximum Supply Cable Size 16 mm Recommended RCD Rating 30 mA tripping current Reco...

Страница 7: ...on within the shower area and is fitted with a pressure relief valve It must be positioned over a water catchment area with the controls at a convenient height for the user 6 The shower must be fitted...

Страница 8: ...itable Zone of Backflow Risk 30 mm Minimum Toilet or Bidet FC5 Hand Basin FC3 Bath or Shower Tray FC3 Electric Shower 25 mm Minimum 25 mm Minimum 15 A full bore non restrictive servicing valve must be...

Страница 9: ...ins system A separate supply must be provided from the consumer unit to the shower 5 DO NOT supply any other electrical equipment including extractor fans or pumps via this product 6 This shower must...

Страница 10: ...er wall structures such as panels alternative fixings may be required A minimum of 3 fixing screws should be used Remove the three cover retaining screws and the cover Caution Handle the glass cover a...

Страница 11: ...s Ensure the position of these holes do not come in line with any buried cables or pipework Make sure that sufficient electrical supply cable is available for connection to the terminal block Drill an...

Страница 12: ...ocated Do not overtighten screws Caution Handle the glass cover assembly with care Do not use alternative screws to secure the cover This can cause internal damage to the appliance Do not seal around...

Страница 13: ...13 Cold Water Supply Pipe Bottom Entry Fixing Screw Holes For Cover Retaining Screws Terminal Block Inlet Connector Assembly Heater Tank...

Страница 14: ...l temperature Turn the control slowly Temperature remains cool and flow is reduced Electrical supply is turned off at the mains 0 5 Secs 1 4 3 2 6 5 9 8 7 Before carrying out the commissioning procedu...

Страница 15: ...automatically The shower will purge water from its tank for a few seconds Residual water may drain over a few minutes Set control to III 5 10 Secs 0 5 Secs 13 15 14 16 Press STOP 18 19 Note A slight...

Страница 16: ...the lower the flow rate and vice versa Heated water is produced by adjusting the flow of cold water passed through a heater tank The shower has three heater settings USER INSTRUCTIONS How Your Electri...

Страница 17: ...cross the range from hot to cold whilst also dealing with fluctuations in electrical and water supplies As a result there is a temperature limit the shower cannot go beyond For safety this temperature...

Страница 18: ...this guide for details 9 The shower hose must be checked regularly and replaced if damaged refer to the user maintenance section towards the rear of this guide for details 10 DO NOT store bathroom ite...

Страница 19: ...ments to reach the handset 6 Press STOP button Shower will continue to run for a few seconds before stopping 7 Isolate power _ _ Note At the end of every shower make sure that the shower head points i...

Страница 20: ...uired operating parameters refer to section Specifications For a cold shower select I For a summer warm shower select II For a winter warm shower select III During extremes of mains water supply tempe...

Страница 21: ...d o r appliance isolating valve is fully turned on Temperature dial or Heater setting too high Turn the heater selector knob to setting II or turn the temperature control until a cooler temperature i...

Страница 22: ...7 bar Note If other appliances are operating pressure may drop below 0 7 bar Other outlets e g toilet garden hose washing machine etc drawing water while the shower is being used Turn off other applia...

Страница 23: ...place parts as necessary Water will not turn off ON ANY Inlet valve solenoid or start stop switch faulty Replace as necessary Supply pressure below 0 2 bar Contact local water company Check mains wate...

Страница 24: ...f water Unscrew the hose from the showerhead and the shower outlet Inspect the hose Cleaning Many household cleaners contain abrasives and chemical substances and should not be used for cleaning plate...

Страница 25: ...y Refit in reverse order making sure the Filter is screwed fully home Do not overtighten Make sure plumbing connections are sealed before restoring electricity supply Refit the cover making sure it is...

Страница 26: ...d ACCESSORIES Shower Seat White 2 1536 128 White Chrome 2 1536 129 For use in or out of the showering area Note Must be installed onto a solid wall Shower seat folds up when not in use Double Outlet C...

Страница 27: ...062 416 38 416 41 416 48 416 51 872 01 872 28 1563 507 1563 539 A A A A A A A A A A 1563 534 1563 519 1634 052 1634 102 1634 103 1563 533 1563 537 1563 538 B B B B B 1634 015 Mira Alero Spare Parts D...

Страница 28: ...ot work correctly refer to this manual for fault diagnosis and check that it is installed and commissioned in accordance with our instructions If this does not resolve the issue contact us for help an...

Отзывы: