988754

Rev * 08/16

14N845 U.S. Route 20, Pingree Grove, IL 60140 USA

Phone (800) 323-9420 - www.minutemanintl.com

A Member of the Hako Group

“Excellence Meets Clean”

Minuteman is a Full Line Manufacturer of Sweepers and Scrubbers,

for Industrial Facilities.

Содержание TRS17

Страница 1: ...Parts and Instruction Manual TRS17 Total Recovery System ...

Страница 2: ...i 85 GPM 480 psi nozzle tĂƚĞƌ ŝŌ 120 dĂŶŬ ŽŶƐƚƌƵĐƟŽŶ Polyethylene ĂƐĞƉůĂƚĞ aluminum ZĞĂƌ tŚĞĞůƐ 10 non marking ĂƐƚĞƌƐ 4 locking WŽǁĞƌ ŽƌĚ ϱϬ Ō ŝŵĞŶƐŝŽŶƐ 39 H x 37 L x 22 W tĞŝŐŚƚ 108 lbs ůĞĐƚƌŝĐĂů ƌĂǁ 14 5 amps sĂĐƵƵŵ ŽůƵƟŽŶ ŽƐĞ 25 tĂŶĚ Swivel wand with squeegee brush head WƌĞƐƐƵƌĞ ƵŶ Included ŝdžƚƵƌĞ ƌLJŝŶŐ ŽƐĞ 25 x 1 5 Diameter tĂƌƌĂŶƚLJ ϯ LJĞĂƌ ƉĂƌƚƐ Ϯ LJĞĂƌƐ ůĂďŽƌ ůŝĨĞƟŵĞ ŽŶ ďŽĚLJ SPECIFICATIONS ...

Страница 3: ...CTION 4 SAFETY INSTRUCTIONS 5 GFCI 7 GROUNDING 9 MAINTENANCE 10 MACHINE OVERVIEW 12 OPERATION 14 UPPER ASSEMBLY 18 UPPER ASSEMBLY BOM 19 UPPER ASSEMBLY BOM page 2 20 LOWER ASSEMBLY 21 LOWER ASSEMBLY BOM page 1 22 LOWER ASSEMBLY BOM page 2 23 LOWER ASSEMBLY BOM page 3 24 Warranty 26 ...

Страница 4: ...R NEW BURNISHER Read the manual carefully and completely before attempting to operate the unit This manual has important information for the use and safe operation of the machine Keep this manual handy at all times This equipment has been engineered and manufactured to provide excellent performance and service To ensure that your equipment will continue to perform as intended t Maintain equipment ...

Страница 5: ... a heated location only t Do not use the machine for dry vacuuming t Use defoamer at all times to prevent damage to the vacuum motor t Do not use water in excess of 130 F 54 C in the solution tank t To prevent seal damage and chemical build up to the pump system run clean water through the solution lines after each day s use t Use only commercially available carpet cleaning solutions and defoamer ...

Страница 6: ... is not a toy Keep away from children t Do not pull by the power or use power cord as a handle Always unplug by grabbing the plug and pulling do not unplug by pulling the power cord t Inspect cord for damage Do not use damaged cords Connect only to properly grounded outlets t Keep hair fingers loose clothing and body parts away from moving parts and openings t Turn off all controls before disconne...

Страница 7: ...e electrical system has been disabled you will not be able to run the TRS 17 at all until you reset the GFCI Before resetting It is best practice to investigate the cause of a GFCI tripping the circuit Possible causes and solutions are t Your equipment has become wet and moisture has come in contact with the electrical system Take unit to an authorized repair location for servicing t Your machine ...

Страница 8: ...Although the GFCI function works on its own it is necessary to test for proper function of your GFCI periodically To do this 1 Plug your equipment to an appropriate wall plug 2 Press the TEST button on the GFCI panel 3 Turn on the switches for PUMP and MOTOR located on the switch panel on the handle If your motors turn on then the GFCI is NOT working properly do not use the equipment until this fu...

Страница 9: ...inances WARNING Connecting the equipment to an improperly grounded outlet can result in an increased risk of electric shock A qualified electrician should be consulted if you are unsure that the outlet is properly grounded Do not modify the plug provided with the equipment If it will not fit the outlet have a proper outlet installed by a qualified electrician This appliance is designed for use on a 1...

Страница 10: ...ord for damage Do not use machine with a damaged cord PERIODIC MAINTENANCE t Use only chemicals safe for extractors t Adhere to the appropriate mix ratios for all chemicals t Do not add chemical to the solution tank use the chemical feed system or pre spray t For optimal performance it is suggested that the operator flush the system after every job or at the end of the day t Pump seals and valves ...

Страница 11: ...maged cord or plug If appliance is not working as it should has been dropped damaged left outdoors or dropped into water return to service center for inspection and repair x Do not pull or carry by cord use cord as handle close a door on cord or pull cord around sharp edges or corners Do not run this TRS 17 over cord Keep cord away from heated surfaces x Do not unplug by pulling cord To unplug gra...

Страница 12: ...s barb 8 Feed hose line for chemical with threaded bottle cap secures the feed hose line to the chemical bottle 9 Bottle holder for chemical feed system Holds up to a one gallon chemical bottle 10 GFCI breaker Interrupts and disables the electrical system if a ground leak is detected 11 Chemical dispensing valve Select between SOAP and RINSE by turning to left or right as marked 12 Male twist lock...

Страница 13: ...Page 13 Parts and Instruction Manual TRS17 Total Recovery System 3 2 1 4 8 6 5 9 10 11 12 13 14 15 16 17 18 7 ...

Страница 14: ...T FRVJQQFE XJUI UISFBEFE JOTFSUT QSF JOTUBMMFE JO UIF CPEZ 5IF UXP MBSHFS SBDLT BSF JOTUBMMFE UPXBSE UIF GSPOU PG UIF NBDIJOF POF QFS TJEF BOE UIF UXP TNBMMFS SBDLT BSF JOTUBMMFE UPXBSE UIF SFBS BMTP POF QFS TJEF Opening the machine 5IJT VOJU DBO CF PQFOFE CZ TJNQMZ SFNPWJOH UXP CPMUT MPDBUFE PO UIF CBDL PG UIF NBDIJOF 5IF VOJU XJMM PQFO GPSXBSE CZ MJGUJOH VQ PO UIF IBOEMF G ZPV OFFE UP PQFO UIF V...

Страница 15: ...solution tank of your TRS 17 with sufficient water for the task at hand 2 Connect solution hose and accessory pressure gun 3 Select the appropriate tip and install on the cap of the chemical feed 8 on page 7 4 Place a bottle into bottle holder 9 on page 7 5 Take the feed tube attached to the cap 8 on page 7 and place it inside the bottle 6 Take the cap from 8 on page 7 and thread it onto the bottl...

Страница 16: ... TRS 17 is equipped with two dedicated tools for liquid recovery The squeegee brush wand and the Gulper tool 1 Connect recovery vacuum hose to the recovery inlet barb 7 on page 7 2 Place the vacuum switch see 18 on page 7 into the ON position 3 Using either the squeegee brush wand or the Gulper tool to extract the liquid from the surface see page 8 4 Monitor the levels in the recovery tank and emp...

Страница 17: ...Page 17 Parts and Instruction Manual TRS17 Total Recovery System NOTES ...

Страница 18: ...Page 18 Parts and Instruction Manual TRS17 Total Recovery System UPPER ASSEMBLY 756 833 5 ...

Страница 19: ...C00234 1 WASHER FENDER 1 4 SS 11 C00238 7 1 4 ID SEALING WASHER 12 C00288 4 SCREW 1 4 20 X 1 5 FLAT HEAD 13 C00288 1 4 SCREW 1 4 20 X 2 25 FLAT HEAD 14 C00295 1 2 10 X 3 4 SHEET METAL SCREW SS 15 C00313 4 1 4 20 X 3 4 HEX BOLT 16 C00316 1 SCREW 1 4 20 X 3 4 PH SS 17 C02251 1 JAM NUT 1 4 20 SS 18 C02282 4 HEX BOLT 1 4 20 X 1 1 2 19 C11144 2 SCREW 1 4 20 X 2 SS 20 C11167 2 1 4 20 X 3 4 SCREW SS 21 C...

Страница 20: ...128 2 DRAIN VALVE GASKET 36 E11836 1 GASKET RECOVERY TANK LID 37 F11785 1 MM 1 LID RECOVERY TANK 38 F11786 1 MM 1 HANDLE 39 F11787 1 MM 1 SOLUTION TANK 40 F11788 1 MM 1 RECOVERY TANK 41 F11791 1 MM 1 LID SOLUTION TANK 42 H13699 1 DECAL MINUTEMAN WHITE 43 K00665 1 1 1 1 2 HOSE ADAPTER 44 K00666 1 1 1 2 90 DEGREE ELBOW 45 K00672 1 PVC PIPE 1 5 SCH40 1 3125 46 K00672 1 1 PVC PIPE 1 1 2 X 2 25 SCH40 4...

Страница 21: ...Page 21 Parts and Instruction Manual TRS17 Total Recovery System LOWER ASSEMBLY 756 6 ...

Страница 22: ... NIPPLE 25MP X 125MP 11 A00134 1 90 DEGREE ELBOW 24B X 125MP 12 A00135 1 TEE 125FP X 125FP X 125MP 13 A00161 1 TEE 25FP X 25FP X 25FP 14 A00168 18 1 BUSHING 25M X 125F 15 A12917 2 ELBOW 25F X 375M NPT 16 A12960 2 NIPPLE HEX 25 X 25 BRASS 17 A12964 1 COUPLER 25 BRASS 18 A13078 1 PLUG MALE 3 8 19 A13430 1 BARB ELBOW 375MP X 5BARB 20 A13688 1 BALL VALVE 3 WAY 125 21 B00192 2 TIE HOLDER W ADHESIVE 22 ...

Страница 23: ...89 3 HEX BOLT 1 4 20 X 4 1 2 39 C11244 2 WASHER 9 16 ID X 1 5 OD 40 C11955 1 WASHER 10 41 C13026 1 SCREW 10 32 X 1 HEX 42 C13120 2 8 32 HEX NUT W LOCK WASHER 43 D11134 1 1 PLATE VACUUM BASE 44 D11835 1 PLATE PUMP 45 D13188 1 SHAFT WHEEL 18 X 0 625 46 D13347 1 BRACKET 47 D13620 1 PLATE REGULATOR 48 D13684 1 BRACKET WAND 49 E11128 1 DRAIN VALVE GASKET 50 E13867 4 SANDWICH MOUNT NEOPRENE 51 F11178 1 ...

Страница 24: ...8 4 SCREW CLAMP 6 1 2 3 4 70 J11863 1 HOSE INTERCOOLER 71 J11933 1 HOSE POLYWIRE PVC 1 2 ID 72 J12932 1 CRIMP 1 4 X 1 4 MPT SWIVEL 73 J13152 1 CLAMP HOSE DOUBLE GRIP 74 J14016 1 TUBING CLEAR 1 4 ID 1 2 OD 5FT 75 2 HOSE ASSEMBLY J00580 1 HIGH PRESSURE TEMP HOSE 1 4 X 10 J00660 2 SWAGE FITTING 25FP 76 1 HOSE ASSEMBLY 25MP X 25FP 10 J00580 1 HIGH PRESSURE TEMP HOSE 1 4 X 10 J00659 1 SWAGE FITTING 25M...

Страница 25: ...ects to hose 4 on this page 2 Part K13686 Gulper tool used to extract large volumes of water Connects to hose 4 on this page 3 Part 00604 35HPA 35FT high pressure solution line Connects to quick disconnect on CR2 16 on page 4 4 1BSU 00618 4A 35 FT Vacuum Hose Connects to vacuum hose inlet barb on CR2 7 on page 4 5 Part 00618 5A 35ft Blower hose Connects to Exhaust port on CR2 13 on page 4 6 Part 9...

Страница 26: ...HDOWK KD DUG H LVWV ZLWKRXW RULJLQDO HTXLSPHQW UHSODFHPHQW OO ZDUUDQWHG LWHPV EHFRPH WKH VROH SURSHUW RI 0LQXWHPDQ RU LWV RULJLQDO PDQXIDFWXUHU ZKLFKHYHU WKH FDVH PD EH 0LQXWHPDQ GLVFODLPV DQ LPSOLHG ZDUUDQW LQFOXGLQJ WKH ZDUUDQW RI PHUFKDQWDELOLW DQG WKH ZDUUDQW RI ILWQHVV IRU D SDUWLFXODU SXUSRVH 0LQXWHPDQ DVVXPHV QR UHVSRQVLELOLW IRU DQ VSHFLDO LQFLGHQWDO RU FRQVHTXHQWLDO GDPDJHV 7KLV OLPLWHG Z...

Страница 27: ... GD V FHSWLRQV 0RGHO 3DUWV DERU 3RO 7UDYHO 3RUW 6FUXE DOO PRGHOV U PRQWKV UV GD V 6 ORZHU U U 3KHQRP XDO 0RWRU 8SULJKW 9DFXXPV UV UV SORVLRQ 3URRI 9DFXXP U U 3URSDQH XUQLVKHU U U GD V 7UDYHO KRXUV PD 6WDQG DORQH DWWHU KDUJHUV 2QH HDU 5HSODFHPHQW 3DUWV 1LQHW GD V DWWHULHV PRQWKV IXOO UHSODFHPHQW PRQWKV SUR UDWH 3RO SURS OHQH 3ODVWLF 7DQNV U ZDUUDQW QR DGGLWLRQDO ODERU ...