29

28

120VAC

1500VA
1050W

Protection

Waveform Type

Over-Current, Short-Circuit Protected and Latching Shutdown

Simulated Sine Wave

Frequency

60Hz, ±0.5Hz (unless synchronized to utility)

Nominal Voltage

Maximum Power Capacity

6-10 ms Typical

>96% (Full Load)

Resettable Circuit Breaker

60 Hz, ±6Hz

0 - 150VAC

90 - 150VAC

103 - 136VAC

Transfer Time

Efficiency (Line Mode)

Protection

Frequency Limits

Voltage Range

Acceptable Input voltage

PRO1500RT2U

Model Number

SYSTEM SPECIFICATIONS

Voltage Range

Topology

Line-Interactive, Simulated Sine Wave

OUTPUT NON-BATTERY OPERATION

INPUT

Number of Phase

Single (1

 

2W +G)

Nominal Voltage

120VAC

Low Voltage Transfer Point

89V resets to Utility Power at 94V or higher

High Voltage Transfer Point

151V resets to Utility Power at 146V or lower

Voltage Regulation

120VAC: ±13.3%

Frequency Range

60Hz: 54 - 66Hz

OUTPUT BATTERY OPERATION

Voltage Regulation

120VAC ±5% (until Low Battery Warning)

Overload Capacity

AC Mode:  110% for 1-minute then shutdown, 150% Shutdown Immediately

PRO2000RT2U

2000VA
1400W

REGULATORY COMPLIANCE

Safety and Approvals

cTUVus (Conforms to UL1778 5th Edition & CSA 22.2 no. 107.3-
14 / R: 2014), FCC Class B, CE certified, Energy Star certified,
RoHS2 (EU Directive 2011/65/EU)

PRO750RT2U PRO1000RT2U

750VA
525W

1000VA
700W

DC Mode:  110% for 20-seconds then shutdown, 150% Shutdown Immediately

Chapter 8:  Specifications

Power Cord (10ft)

NEMA 5-15P

NEMA 5-20P

Receptacles (NEMA)

8:  5-15R

6:  5-15/20R
1:  L5-20R

BATTERY SYSTEM

Typical Recharge Time

Typical Battery Life

3 to 5 years. 

 

Environmental factors do affect battery life.  High

temperatures, poor utility power, and frequent, short duration
discharges have a negative impact on battery life.

8-hours to 90% capacity from a full load discharge

Battery Type

Sealed, Non-Spillable, Maintenance Free, Value Regulated Lead Acid

Runtime: Half Load (minutes)

Runtime: Full Load (minutes)

SURGE PROTECTION AND FILTERING

Audible Noise at 1 m (3 ft.)

Noise Filter

Surge voltage let-through (as a
percentage of an applied ANSI
C62.41 Cat. A ±2 kV)

Response Time

Surge Current Capability

UPS Surge Energy Rating

960 J

0 ns (instantaneous) normal mode; <5 ns common mode

< 0.30%

>45db normal and common mode EMI/RFI suppression

<45 dBA

6500 Amps total

 

(one time 8 to 20us waveform)

PHYSICAL

Weight - Net

Size - Net
L X W X H

Size - Shipping
L X W X H

Weight - Shipping

16.1 X 18.9 X 3.4"
410 X 480.6 X 86.2 mm

22.4 X 21.7 X 9.4"
570 X 550 X 240 mm

48.7 lbs
22.1 Kgs

56.4 lbs
25.6 Kgs

ENVIRONMENTAL

Operating/Storage Humidity

5- 95% Non-Condensing

Storage Elevation

0 to 15,000m (0 to +50,000 ft)

Storage Temperature

-15 to +45

°

C (+5 to +113

°

F)

Operating Temperature

31.3 lbs
14.2 Kgs

37.5 lbs
17.0 Kgs

4

14

4

14

35.7 lbs
16.2 Kgs

62.8 lbs
28.5 Kgs

70.5 lbs
32.0 Kgs

41.9 lbs
19.0 Kgs

4

14

5

15

20.1 X 18.9 X 3.4"
510 X 480.6 X 86.2 mm

26.4 X 22.4 X 9.4"
670 X 570 X 240 mm

Battery Module Part #

BM0075

BM0072

BM0073

BM0074

Operating Elevation

0 to 40

°

C (+32 to +104

°

F)

0 to 3000m (0 to +10,000 ft)

Network/Phone/Fax/Modem
transient voltage surge protection

10/100/1000 Base-T network, single line phone, Fax or Mo-
dem. 1-in / 1-out combo RJ11/45 connectors

Coax transient voltage surge
protection

Cable modem , CATV converter, DSS receiver, DVR.
1-in / 1-out

Содержание PRO1000RT2U

Страница 1: ...User s Manual PRO RT 2U Series UPS Para Systems Inc 1455 Lemay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000526 R2...

Страница 2: ...2 2 Controls and Indicators 8 3 Installation 11 4 Operation 18 5 Obtaining Service 22 6 Troubleshooting 23 7 Replacing the Battery 24 8 Specifications 28 9 Limited Product Warranty 30 A1 Declaration...

Страница 3: ...ettra de correctement installer le syst me pour atteindre son rendement maximum en toute s curit CAUTION Connect the UPS to a two pole three wire grounded utility power AC wall outlet The receptacle m...

Страница 4: ...test Once the UPS has passed its self test the UPS will be ready for normal operation When the UPS is in the AC mode Press and then release the On Off Test button during the audible alarm s first beep...

Страница 5: ...prior written permission of Para Systems Given that Para Systems will continuously improve and de velop the product changes may be made to the information in this Manual at any time without obligation...

Страница 6: ...layed and the UPS will sound a constant alarm to indicate that there is an Overload condition Battery Capacity Bar Graph Displays the amount of Battery Ca pacity available in the AC and Battery mode a...

Страница 7: ...tacles are electrically wired into two segments to support the Load Shedding Function Labeled Load 1 Load 2 7 TheAlways On Battery Backup output receptacles LabeledAlways On does not support the Load...

Страница 8: ...nstable due to the weight distribution 2 The Rackmount Configuration is complete See Connecting your Equipm ent CONNECTING THE BATTERIES QUALIFIED SERVICE PERSONNEL ONLY Please read all of the WARNING...

Страница 9: ...CONFIGURATION The tower configuration allows the user to install the UPS in the up right position The tower brackets are provided with the UPS Use two or more people when installing the UPS the UPS i...

Страница 10: ...arge electrical device into the output receptacles of the UPS COAX PROTECTION CONNECTION OPTIONAL Connect a cable modem CATV converter DSS receiver or DVR to the coax connectors on the rear panel of t...

Страница 11: ...will blink During normal AC operation the UPS will quietly and confidently protect your system from power anomalies The UPS will charge the batteries with the UPS in the on or off position when the UP...

Страница 12: ...tests the battery s condition If the battery is weak bad or disconnected the Weak Bad Battery icon will illuminate and the Battery Capacity Bar Graph will turn off the LCD screen will display error c...

Страница 13: ...r the UPS Check the specifications Chapter 5 Obtaining Service IF THE UPS REQUIRES SERVICE 1 Use the Troubleshooting section to eliminate obvious causes 2 Verify there are no tripped circuit breakers...

Страница 14: ...battery system can present a risk of electrical shock These batteries produce sufficient current to burn wire or tools very rapidly produc ing molten metal Observe these precautions when replacing th...

Страница 15: ...G 2 FIG 3 7 Disconnect the battery connectors FIG 2 8 Remove the four retaining screws for the battery retaining bracket FIG 2 9 Remove the battery retaining bracket and set aside 10 Grasp the battery...

Страница 16: ...ery Life 3 to 5 years Environmental factors do affect battery life High temperatures poor utility power and frequent short duration discharges have a negative impact on battery life 8 hours to 90 capa...

Страница 17: ...FIT NESS FORAPARTICULAR PURPOSE Some states do not permit limitation of implied warranties therefore the aforesaid limitation s may not apply to the purchaser EXCEPT AS PROVIDED ABOVE IN NO EVENT WILL...

Страница 18: ...33 32 Notes Notes...

Отзывы: