![Minuteman ES2832 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/minuteman/es2832/es2832_service-manual_1804221021.webp)
5. Table of Error Codes (SC280000 Models)
0003
For All of these Diagnostic Codes:
0100
1- Turn Off Key switch and disconnect batteries.
0204
2- Wait 1 minute.
0705
3- Reconnect Batteries and turn on key switch.
0706
4- If Diagnostic Code is not cleared, then replace TRIO+ / TRIO+HD control.
0A01
0B02
IMPORTANT!
0B0B
TRIO+ / TRIO+HD can be damaged internally by shorting Batt+ to any of it's Inputs or Outputs.
Check Wiring Harness for shorts before installing a replacement Control.
1704
If replacement control fails, then replace Wiring Harness before installing any more Controls.
1705
1706
1706
1800
1802
1B20
1B21
2102
2103
2D01
3100
Shorted Circuit
Check For Shorts on the Brush and Drive Motor Circuits. Also Water inside of motors.
3101
3102
3103
3104
3105
3200
3201
3210
3211