![Minuteman E Ride 30 Скачать руководство пользователя страница 62](http://html1.mh-extra.com/html/minuteman/e-ride-30/e-ride-30_service-manual_1804310062.webp)
9.3 A4:X51 Plug Assignment
PIN
Plug assignment (measured to battery minus) (X51)
•
g
g
(
y
) (
)
1
not connected
2
Drive control unit release;
U
= 24V or battery voltage if key switch has
closed
3
Drive potentiometer;
U
= 0V
4
Forward drive direction;
U
= 0V after forward mode has been selected
4
Forward drive direction;
U
= 0V after forward mode has been selected
and ‘S8’ drive potentiometer switch and contact on control unit A1 have
closed.
5
Reverse drive direction;
U
= 0V after reverse mode has been selected
5
Reverse drive direction;
U
0V after reverse mode has been selected
and ‘S8’ drive potentiometer switch and contact on control unit A1 have
closed.
6
not connected
62
Содержание E Ride 30
Страница 1: ...Service Manual for the E Ride 30 Training Trouble Shooting Adjustments ...
Страница 37: ...6 Particular Settings currently programmed setting water stage setting error display 37 ...
Страница 76: ...11 Adjustment of the Disk Brake 76 ...
Страница 77: ......
Страница 78: ......
Страница 80: ...13 Notes ...