![Minuteman E Ride 30 Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/minuteman/e-ride-30/e-ride-30_service-manual_1804310056.webp)
9.1 Signal Measuring at
the Drive Control Unit
3.
Speed
The speed attained directly depends on the drive potentiometer which is actuated
via the accelerator pedal.
The max speed with full throttle is:
The max. speed with full throttle is:
Forward ride:
approx. 7.1km/h
Reverse ride:
approx. 3.8 km/h
.
With a free-wheeling drive wheel (jacked machine and cold drive motor)
With a free wheeling drive wheel (jacked machine and cold drive motor),
the parameters are as follows:
Forward ride:
I
≈
12.5A ; drive wheel speed: n
≈
230 rpm
Reverse ride:
I
≈
11.5A ; drive wheel speed: n
≈
130 rpm
To attain a higher final speed in forward ride than in reverse ride, a signal is
transferred to the drive control unit.
56
Содержание E Ride 30
Страница 1: ...Service Manual for the E Ride 30 Training Trouble Shooting Adjustments ...
Страница 37: ...6 Particular Settings currently programmed setting water stage setting error display 37 ...
Страница 76: ...11 Adjustment of the Disk Brake 76 ...
Страница 77: ......
Страница 78: ......
Страница 80: ...13 Notes ...