2
Figure
5-1 the Cleaning Picture of Optics Lens
5.4
Adjustment of the beam delivery
For the sake of the normal usage, the operators should be familiar with the
operation of adjustment, maintenance of the beam delivery optics.
This
laser is a Class 4 laser product (there are warning
labels on the laser unit and the beam path). The
energy density of the beam is high and the output
beam is invisible to the human eye, and never look
directly into the light source or scattered laser light
from reflective surfaces when adjusting the beam
delivery optics and machining. If laser radiation is
exposed to the skin it can burn and cut the flesh. The
adjustment, maintenance of the beam delivery optics
must only be carried out by trained staff.
5.4.1 The principle of the beam delivery and optics adjustment
The beam delivery picture is shown on Figure 5-2.
The output beam must parallel to X axis and 45
o
incident to the center
of mirror A. The beam effluents from the center of mirror A block export
after reflection and goes forward along Y axis. The beam effluents from
the center of mirror B block export after reflection and goes forward along
X axis. The beam effluents from the center of mirror C block export after