![Minotair PENTACARE-V12 Series Скачать руководство пользователя страница 59](http://html.mh-extra.com/html/minotair/pentacare-v12-series/pentacare-v12-series_user-manual-and-installation-manual_1803655059.webp)
© MINOTAIR Ventilation Inc. - www.minotair.com
59
(PENTACARE-V12-OWNER'S MANUAL-2019-Rev-014)
5.
A
DJUSTING
F
ILTER
S
ETTINGS
Press the
P
button for 3 seconds to display the main menu and use the
U
and
D
arrows to
navigate to the “Filters” submenu.
Press
R
to select (Figure 56).
Figure 56
–
Main menu
–
Filter settings.
“F
ILTERS
”
SETTINGS SCREEN
There are 2 available options displayed over several screens. Press
D
or
U
to move the
cursor between options. Once the desired option is selected, press
R
to change the
setting (Figure 57).
Figure 57
–
Examples of options to adjust filter settings.
5.1 Prefilters.
The MINOTAIR must be equipped with manufacturer-approved MERV 8
(G4) prefilters to ensure proper functioning. Two prefilters protect the MINOTAIR
from dust, which can quickly clog its coils and fan blades. The prefilters must be
replaced every three months.
o
Operation
. The number of hours of fan operation since the prefilters were
last replaced. This counter is only active when ventilation is running.
o
Reset counter?
Resets the prefilter counter. There needs to be a reset after
every change of filters, normally after 3 months of ventilation.
5.1.1 Thaw Filter?
At times during the heating season, moisture that comes into
contact with the right coil will frost. The formed ice can make the removal of the
right filter impossible, the latter being jammed in ice. To remove a jammed filter, it
is necessary to defrost the coil. This procedure takes about 3 minutes and will then
allow for filter removal without difficulty.