1: Press the button 5 times quickly, the LED indicator flashes slowly to enter the setting “Min

brightness” mode. The lamp will adjusts to the min brightness automatically.

brightness” mode. The lamp will adjusts to the max brightness automatically.

the max brightness.

The LED indicator will flashes 3 times.

the min brightness.

The LED indicator will flashes 3 times.

2: Hold the button to adjust the brightness of the bulb, select the appropriate brightness to set 

3: Press the button 5 times quickly to confirm it (the min brightness setting is completed).

1: Press the button 10 times quickly, the LED indicator flashes slowly to enter the setting “Max

2: Hold the button to adjust the brightness of the bulb, select the appropriate brightness to set

3: Press the button 10 times quickly to confirm it (the max brightness setting is completed).

Remark: If the setting is not confirmed at Step 3, the setting mode will be exited after 10S. 

1. Z-Wave on / off + dimmer control.

2. Grounded 3-wire power connection for safety.

3. Remember and restore on/off status after power failure.

4. Built-in Z-Wave Plus signal repeater to extend network range

5. S2 security and 700 Z-Wave chip for reliable wireless communication.

6. Work with all certificated Z-Wave controllers.

Min brightness level setting( Refer to Parameter 11)

Max brightness level setting( Refer to Parameter 12)

Features:

devices from other manufacturers and/or other applications. All non-battery operated nodes

This product can be included and operated in any Z-Wave network with other Z-Wave certified

within the network will act as repeaters regardless of vendor to increase the reliability of the

network. This Device supports Lifeline (association group 1) supporting 1 node for lifeline

communication. Group 1 must be assigned the Node ID of the primary controller where

unsolicited notifications will be sent.

The Z-Wave controller should set this association automatically after inclusion.

Lifeline association only supports the “Device Reset Locally” function.

This parameter can access you to set a timer to make the switch turn off

automatically after the switch turns on.The numberentered as value

(LED flashes 3 times when the configuration parameter changed.)

--- Parameter =4, Size=4

Value: 0– 65535(minutes);

Value=0(default) disable

Auto Turn-Off Timer

corresponds to number of minutes. Operation: Set up on the hub.

Z-Wave Dimmer Plug

MP31ZD (ZW39M)

Specification

Input: 125VAC 60Hz

Frequency: 908.42 MHz

Dimmable CFL/LED

Loading: 200W Incandescent 100W

Program button

Press 1x: Manually

Press 3x: Z-Wave Network configuration

for 10 seconds

Reset: Press the button twice then hold it

LED indicator

Blue: Light status indicator

Blue: ADD / Inclusion

Purple: Remove / Exclusion

Warning

Red: Network Failure / Over-temperature

Z-WAVE INTEROPERABILITY

Adding Device To Z-Wave Network for QR CODE

Scan here for SmartStar inclusion

Note: DSK Code can be found on the

packaging box.

Do not remove or damage them.

Z-Wave Network Configuration

Adding Device To Z-Wave Network

Again: If you have issues with pairing / including, please move the device as close as possible to

the hub and try again--you can move to your final location when completed.

Note: If the manual button doesn't light up after pressing 3 times, please reset the

device: click the button twice quickly then hold it at least 10 seconds.

This operation could be done when manual control is functional--single press can turn on/off

the lamp.

2. Once the controller is ready to add your device, press the Manual/ Program button on the

smart plug 3 times quickly.  The blue LED will flash quickly.

1. Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave

network.

Now, you have completed control to turn your fixture ON / OFF according to groups,

schedules and interactive automation programmed by your controller. If your Z-Wave certified

controller features remote access, you can control your fixture from your mobile devices.

Auto-add mode: LED will flash within 30 seconds after the first plug.

1. Follow the instructions for your Z-Wave certified controller to remove a device from the

Z-Wave network.

2. Once the controller is ready to remove your device, press the manual / program button on

the smart plug 3 times quickly.

Manual: Click the button twice quickly then hold it at least 10 seconds. (Reset successfully, light

will flash once.)

Host reset:  Remove it from hub, the device will be restore to factory default.

Association Group 1: Z-Wave Plus Lifeline

Association Group 2: Send Basic Set ON / Off

Over-temperature protection is protection against

overheating of the protected equipment. When the device's

temperature is high, the LED will light up in red and cut

down the power. Please power off the device and use it after

the temperature of the device drops.

Group 1 supports 1 node ID,Group 2 Supports maximum of 5 node ID’s

To Remove The Device

To Return The Device To Factory Defaults

Association Group

Our Products warrant this product to be free from manufacturing defects for a period of one

year from the original date of consumer purchase. This warranty is limited to the repair or

replacement of this product only and does not extend to consequential or incidental damage to

other products that may be used with this product. This warranty is in lieu of all other warranti-

es, expressed or implied. Some states do not allow limitations on how long an implied warranty

lasts or permit the exclusion or limitation of incidental or consequential damage, so the above

limitations may not apply to you. This warranty gives you specific rights, and you may also have

other rights which vary from state to state.

Warranty

Parameter Settings

LED Indicator

This parameter can access you to choose the LED indicator to be on when the plug(light) is

on/off, or LED indicator remains on/off all times.

(LED flashes 3 times when the configuration parameter changed.)

Value=1 --- LED is On when switch (light) is Off.

--- Parameter =2, size =1byte, Default =0

Value=0 (default) LED is On when switch (light) is On.

Value=2 --- LED is always Off.

Value=3 --- LED is always On.