background image

Z-Wave Smart Plug

(2 Channel)

• ZW37 • 

Model: MP20Z

Power: 120V AC, 60Hz

Loading: 10 Amp Max Smart Outlet *1

                   10 Amp Max Smart Outlet *1

Total(Both Outlets): 16 Amp Max

Frequency:  908.42MHz

Put the Z-wave interface controller into “Add” mode,  

triple press the Program button.

 It will be included in 

network. (Once your controller confirmed,  refresh 

the Z-Wave network to optimize performance. )

Put the Z-Wave interface controller into "Remove" 

mode, 

 triple press the Program button

. It will be 

excluded to network.

Press and hold button 5S while power on.

Note: This should only be used in the event your 

network’s primary controller is missing or otherwise 

inoperable.

2. Your device may need to be within 100 feet of the 

controller to be included. If so, include the device 

to the network within 10 feet of the controller 

and relocate it to the desired position in your 

home. Be sure to refresh the network if the 

device is included in this manner.

Add to Z-Wave Network

Remove from Z-Wave Network

1. Plug the device you want to control into the 

Z-Wave Smart plug controlled outlet.

     NOTE: Plug directly into the outlet, do not use 

with extension cords.

To return your switch to factory defaults

100 feet

Features:

Notes:

Program button

Smart outlet*2

Single press :  manually turn 

on/off your device.

Two outlets can remotely 

turn On/Off the 

connected device.

Z-WAVE INTEROPERABILITY

This product can be included and operated in any Z-Wave network with other Z-Wave certified devices 

from other manufacturers and/or other applications. All non-battery operated nodes within the 

network will act as repeaters regardless of vendor to increase the reliability of the network.

This Device supports Lifeline (association group 1) supporting 1 node for lifeline communication. 

Group 1 must be assigned the Node ID of the primary controller where unsolicited notifications will be 

sent. The Z-Wave controller should set this association automatically after inclusion. 

Lifeline association only supports the “Device Reset Locally” function. Refer to the instructions of your 

controller for any available details on how this can be set.

1. Z-Wave on/off control of 2 electrical devices.

2. Two Z-Wave controlled AC outlet for standard 

incandescent lighting, CFL/LEDs, fans or small 

appliances(1800W Resistive).

3. Grounded 3-wire power connection for safety.

4. Manual/wireless on/off and brightness control.

5. Remembers and restores on/off status after power 

failure. 

6. Built-in Z-Wave Plus signal repeater to extend 

network range. 

7. S2 security and 500 Z-Wave chip for reliable 

wireless communication.

8. Work with all certificated Z-Wave controllers.

1. ADD/REMOVE: 

Triple press the button, LED will brink within 30s

press 1x: On/Off the Right outlet

press 2x: On/Off the Left outlet

press 3s: On/Off simultaneously.

2. Factory setting:

Manual: Click Z-Wave button 2 times quickly, and hold 

for at least 10 seconds

Host reset: Remove it from the host and the device is 

factory reset.

3. Association 

(Support 3 group, each group max 

support 2 devices) LED flash twice to confirm its setup 

successfully.

                                Group 1  lifeline

                                Group 2  Left outlet sends a basic set

                                Group 3  right outlet sends a basic set

4. LED Indicator

Manual: Click Z-Wave button 6 times quickly to change 

between values 0,1, 2 

Parameter =1, size =1byte, value=00  Default out on,led on, 

                                                        

value=01  out on,led off 

                                                        value=02  led no work

5. Auto Turn-Off Timer

Parameter =2, Size=4

Values: 1 – 65535 (minutes);  

                                                                turn off the left outlet

Parameter =3, Size=4

Values: 1 – 65535 (minutes) 

                                                                turn off the right outlet

6. Auto Turn-On Timer

Parameter =4, Size=4

Values: 1 – 65535 (minutes);  

                                                                turn on the left outlet

Parameter =5, Size=4

Values: 1 – 65535 (minutes) 

                                                                turn on the right outlet

Отзывы: