![Minolta DI750 - SERVICE Скачать руководство пользователя страница 92](http://html.mh-extra.com/html/minolta/di750-service/di750-service_service-manual_1802954092.webp)
1 - 71
36 ADJUSTMENT
1 ADJUSTMENT
[13] Recall Standard Data
(Image Adjustment)
Restoring image adjustment settings to standard val-
ues (data after process adjustment).
[14] Running Test Mode
Testing continuous copy operation.
Select
3
Running Test Mode in the 36 Mode Menu
Screen.
This adjustment consists of the following items:
1.
Intermittent copy mode
In this mode, the machine goes into the copy
ready state after completing a set number of copy
operation, waits 0.5 sec, and then repeats the
same operation.
2.
Paperless intermittent copy mode
In this mode, the machine makes copies at approxi-
mately the same timing as for normal copy without
performing paper detection or jam detection. In
addition, similar to intermittent copy mode, the ma-
chine goes into the copy ready state after complet-
ing a set number of copy operation, waits 0.5 sec,
and then repeats the same operation.
3.
Paperless mode
In this mode, the machine makes copies at approxi-
mately the same timing as for normal copy without
performing paper detection or jam detection.
4.
Paperless endless mode
In this mode, the copy quantity is set to infinity.
In addition, similar to Paperless mode, the ma-
chine makes copies at approximately the same
timing as for normal copy without performing
paper detection or jam detection.
5.
Running mode
This mode consists of Paperless endless mode
with repetitive optical scan and auto paper feed
tray change.
Step
Operation
1
Enter the 36 mode.
2
[36 Mode Menu Screen]
Press
3
Running test mode.
3
[Running Test Mode Menu Screen]
Press mode keys
1
to
5
.
4
[Copy Screen]
Press the Start button.
5
Check the copy operation and then press
the Stop/Clear button to stop.
6
Turn off the main switch and exit Run-
ning Test Mode.
Step
Operation
1
Enter the 36 mode.
2
[36 Mode Menu Screen]
Press
2
Image adjustment.
3
[Image Adjustment Menu Screen]
Select
7
Recall standard data.
4
[Recall Standard Data Screen]
Press the
YES
key.
Various data are restored to standard
values.
5
Press the
PREVIOUS SCREEN
key to re-
turn to the Image Adjustment Menu
Screen.
Di750Ver.3field01be.p65
01/07/18, 17:43
71
Содержание DI750 - SERVICE
Страница 1: ...L r 3 ...
Страница 6: ...CONTENTS 1 ADJUSTMENT 2 ISW 3 SERVICE 4 ELECTRIC PARTS LIST Blank page ...
Страница 20: ...1 ADJUSTMENT ADJUSTMENT 1 ...
Страница 21: ...1 ADJUSTMENT Blank page ...
Страница 124: ...1 103 OTHER ADJUSTMENT 1 ADJUSTMENT Blank page ...
Страница 128: ...1 107 OTHER ADJUSTMENT 1 ADJUSTMENT Blank page ...
Страница 162: ...1 141 OTHER ADJUSTMENT 1 ADJUSTMENT Blank page ...
Страница 163: ...2 ISW ISW 2 ...
Страница 164: ...2 ISW Blank page ...
Страница 177: ...3 SERVICE SERVICE 3 ...
Страница 178: ...3 SERVICE Blank page ...
Страница 180: ...3 SERVICE Blank page ...
Страница 203: ...4 ELECTRIC PARTS LIST ELECTRIC PARTS LIST 4 ...
Страница 204: ...4 ELECTRIC PARTS LIST Blank page ...
Страница 213: ...4 9 PARTS LAYOUT DRAWING 4 ELECTRIC PARTS LIST Blank page ...
Страница 227: ...4 23 CONNECTOR LAYOUT DRAWING 4 ELECTRIC PARTS LIST Blank page ...
Страница 233: ...4 29 JAM CODE LIST 4 ELECTRIC PARTS LIST Blank page ...
Страница 246: ...4 42 JAM CODE LIST 4 ELECTRIC PARTS LIST Blank page ...
Страница 276: ...4 72 ERROR CODE LIST 4 ELECTRIC PARTS LIST Blank page ...
Страница 279: ......