![Minolta DI750 - SERVICE Скачать руководство пользователя страница 106](http://html.mh-extra.com/html/minolta/di750-service/di750-service_service-manual_1802954106.webp)
1 - 85
47 ADJUSTMENT
1 ADJUSTMENT
3.
Multi mode
This mode is entered from the 47 mode. It ena-
bles multiple I/O checks using a single I/O check
code.
4.
Multi mode operation method
Enter the 47 mode and proceed as follows:
(1) To check the input
a. Using the copy quantity button, enter the
check code for the desired I/O.
b. The 47 mode code appears enclosed in <>
in the second row of the message area.
c. Press the Utility button.
d. “-” (hyphen) will be displayed following the 47
mode code enclosed in <>. (only codes that
support the multi mode can be used)
e. Enter the desired multi number using the copy
quantity button. (Refer to the multi mode list.)
f. The multi number will be displayed enclosed
in <>, following the 47 mode code and “-”.
I/O Check Mode
<10-01> IN:-- OUT:--
g. Press the Utility button.
h. Check the status of the code displayed as H
or L after “IN:” in the second row of the mes-
sage display area.
(2) To check the output
a. Press the Start button.
b. Press the Stop/Clear button after checking the
output.
(3) Ending multi mode
a. Turn off the main switch to exit the 47 mode
(multi mode).
Step
Operation
1
Enter the 47 mode.
2
[47 Mode (I/O Check Mode) Screen]
Use the copy quantity button and enter the
code.
3
Press the Utility button.
4
Enter the multi number using the copy
quantity button.
5
Press the Utility button.
6
Check the input signal check result dis-
played after “IN:” in the second row of
the message area.
7
To perform the output check, press the
Start button to check the output load.
8
Press the Stop/Clear button to end the
output check.
9
Turn off the main switch to exit the 47
mode.
Note 1: To check another multi number in the
same code, press the Utility button after
completing step 8. Only data enclosed in
<> will be cleared. Then enter another
multi number.
Note 2: To return to the normal 47 mode, press
the Stop/Clear button while holding down
the Utility button after completing step 8.
(The screen will return to the 47 mode
initial state.)
Di750Ver.3field01ce.p65
01/07/18, 17:44
85
Содержание DI750 - SERVICE
Страница 1: ...L r 3 ...
Страница 6: ...CONTENTS 1 ADJUSTMENT 2 ISW 3 SERVICE 4 ELECTRIC PARTS LIST Blank page ...
Страница 20: ...1 ADJUSTMENT ADJUSTMENT 1 ...
Страница 21: ...1 ADJUSTMENT Blank page ...
Страница 124: ...1 103 OTHER ADJUSTMENT 1 ADJUSTMENT Blank page ...
Страница 128: ...1 107 OTHER ADJUSTMENT 1 ADJUSTMENT Blank page ...
Страница 162: ...1 141 OTHER ADJUSTMENT 1 ADJUSTMENT Blank page ...
Страница 163: ...2 ISW ISW 2 ...
Страница 164: ...2 ISW Blank page ...
Страница 177: ...3 SERVICE SERVICE 3 ...
Страница 178: ...3 SERVICE Blank page ...
Страница 180: ...3 SERVICE Blank page ...
Страница 203: ...4 ELECTRIC PARTS LIST ELECTRIC PARTS LIST 4 ...
Страница 204: ...4 ELECTRIC PARTS LIST Blank page ...
Страница 213: ...4 9 PARTS LAYOUT DRAWING 4 ELECTRIC PARTS LIST Blank page ...
Страница 227: ...4 23 CONNECTOR LAYOUT DRAWING 4 ELECTRIC PARTS LIST Blank page ...
Страница 233: ...4 29 JAM CODE LIST 4 ELECTRIC PARTS LIST Blank page ...
Страница 246: ...4 42 JAM CODE LIST 4 ELECTRIC PARTS LIST Blank page ...
Страница 276: ...4 72 ERROR CODE LIST 4 ELECTRIC PARTS LIST Blank page ...
Страница 279: ......