![Minolta DI750 - SERVICE Скачать руководство пользователя страница 72](http://html.mh-extra.com/html/minolta/di750-service/di750-service_service-manual_1802954072.webp)
1 - 51
36 ADJUSTMENT
1 ADJUSTMENT
[1] Setting Method
A special adjustment mode called the 36 Mode is pro-
vided. This mode is used to perform various adjust-
ments.
1.
Turn off the main switch.
2.
Turn on the main switch while holding down both
paper quantity buttons 3 and 6. The 36 Mode
Menu Screen appears.
At this point, you are in 36 mode and normal copy op-
eration is disabled.
[36 Mode Menu Screen]
36 MODE
[2] High Voltage Adjustment
Adjusting the high voltage for charging, transfer, sepa-
ration, and development.
1.
Select
1
Process Adjustment in the 36 Mode
Menu Screen to display the Process Adjustment
Menu Screen.
2.
Press
1
High Voltage Adjustment in the Proc-
ess Adjustment Menu Screen to display the High
Voltage Adjustment Menu.
3.
High Voltage Adjustment consists of the follow-
ing:
[1] High Voltage Auto Adjustment
[2] High Voltage Adjustment (Charge)
[3] High Voltage Adjustment (Transfer)
[4] High Voltage Adjustment (Separation AC)
[5] High Voltage Adjustment (Separation DC)
[6] High Voltage Adjustment (Charging grid
voltage)
[7] High Voltage Adjustment (Bias of
development)
[8] Transfer Guide Confirm
4.
Press the number button corresponding to the
item to be adjusted.
The adjustment screen of the selected item is
displayed.
5.
When adjustment completes, the screen returns
to the High Voltage Adjustment Menu Screen.
6.
Press the
PREVIOUS SCREEN
key in the High Volt-
age Adjustment Menu Screen to return to the
Process Adjustment Menu Screen.
3.
Press the number key corresponding to the item
to adjust.
The setting screen for each item is displayed.
4.
Enter data in each adjustment screen.
5.
If there are several adjustment items, press the
NEXT ITEM
or
PREVIOUS ITEM
key to select the
desired item. If there are more screens, press
the key displayed on screen to change screen.
6.
Enter data and press the
SET
key if it is avail-
able, to confirm your entry.
7.
Press the
PREVIOUS SCREEN
key to end adjust-
ment.
8.
Turn off the main switch and exit the 36 mode.
9.
The new adjustment values take effect after re-
starting the machine.
Di750Ver.3field015e.p65
01/07/18, 17:42
51
Содержание DI750 - SERVICE
Страница 1: ...L r 3 ...
Страница 6: ...CONTENTS 1 ADJUSTMENT 2 ISW 3 SERVICE 4 ELECTRIC PARTS LIST Blank page ...
Страница 20: ...1 ADJUSTMENT ADJUSTMENT 1 ...
Страница 21: ...1 ADJUSTMENT Blank page ...
Страница 124: ...1 103 OTHER ADJUSTMENT 1 ADJUSTMENT Blank page ...
Страница 128: ...1 107 OTHER ADJUSTMENT 1 ADJUSTMENT Blank page ...
Страница 162: ...1 141 OTHER ADJUSTMENT 1 ADJUSTMENT Blank page ...
Страница 163: ...2 ISW ISW 2 ...
Страница 164: ...2 ISW Blank page ...
Страница 177: ...3 SERVICE SERVICE 3 ...
Страница 178: ...3 SERVICE Blank page ...
Страница 180: ...3 SERVICE Blank page ...
Страница 203: ...4 ELECTRIC PARTS LIST ELECTRIC PARTS LIST 4 ...
Страница 204: ...4 ELECTRIC PARTS LIST Blank page ...
Страница 213: ...4 9 PARTS LAYOUT DRAWING 4 ELECTRIC PARTS LIST Blank page ...
Страница 227: ...4 23 CONNECTOR LAYOUT DRAWING 4 ELECTRIC PARTS LIST Blank page ...
Страница 233: ...4 29 JAM CODE LIST 4 ELECTRIC PARTS LIST Blank page ...
Страница 246: ...4 42 JAM CODE LIST 4 ELECTRIC PARTS LIST Blank page ...
Страница 276: ...4 72 ERROR CODE LIST 4 ELECTRIC PARTS LIST Blank page ...
Страница 279: ......