1. Installing the Copier
Installation Site
To ensure utmost safety and prevent possible malfunctions of the copier, install it in a location which meets
the following requirements.
Power Source
The power source voltage requirements are as follows.
◆
Use a power source with little voltage fluctuation.
Voltage Fluctuation : Within
±
10%, (+6%, -10% (Only AC127V))
Frequency Fluctuation
: Within
±
0.3%
Space Requirements
To ensure easy copier operation, supply replacements and service maintenance, adhere to the recommended
space requirements detailed below.
* Be sure to allow a clearance of 150mm (6 inch) or more at the back of the copier as there is a ventilation duct.
EP1031F (with Semi-automatic Document Handler)
EP1031 (with Original Cover)
◆
A place away from a curtain or the like that
may catch fire and burn easily.
◆
An area where there is no possibility of being
splashed with water or other types of liquid.
◆
An area free from direct sunlight.
◆
A place out of the direct air stream of an air
conditioner, heater, or ventilator.
◆
A well-ventilated place.
◆
A dry place.
◆
A dust-free location.
◆
An area not subject to undue vibration.
◆
A stable and level location.
◆
A place where ammonia or other organic gas
is not generated.
◆
A place which does not put the operator in the
direct stream of exhaust from the copier.
◆
A place which is not near any kind of heating
device.
C1159O002DA
C1159O003DA
921 (36 1/4)
837 (33)
660 (26)
559 (22)
101 (4)
291 (11 1/2)
804 (31 3/4)
304 (12)
500 (19 3/4)
87°
49 (2)
694 (27 1/4)
357 (14)
281 (11)
647 (25 1/2)
303 (12)
281 (11)
849 (33 1/2)
304 (12)
545 (21 1/2)
105°
94 (3 3/4)
291 (11 1/2)
559 (22)
660 (26)
837 (33)
921 (36 1/4)
101 (4)
Unit: mm (inch)
Chapter 1
Safety Notes
2