Dowel Drill
Manual
12
CONTROL &
GAUGES
INSTALLATION
Shut off air pressure. Install in air line with air
flow in direction of arrow on body.
RECOMMENDED SETTINGS
Regulator should read approximately between 4
and 7 PSI. Some adjustment may be necessary.
ADJUSTMENT
Turn adjustment screw clockwise to increase
outlet pressure setting and counterclockwise
to decrease outlet pressure setting. To reduce
pres-sure, first reduce to a pressure less than
that desired, then increase to the desired outlet
pressure.
These products are intended for use in indus-
trial compressed air systems only. Do not use
these products where pressures and tempera-
tures can exceed those listed on the product
label.
LUBRICATOR IS SET AT 4.5 FROM FACTORY. DIFFERENT TEMPERATURES MAY AFFECT FLOW OR OIL.
YOU MIGHT HAVE TO ADJUST LUBRICATOR ACCORDINGLY. BE SURE LUBRICATOR IS SET SO THAT YOU
ALWAYS HAVE A LIGHT FILM OF OIL ON EXHAUST DEFLECTOR.
TO ADJUST LUBRICATOR, DISCONNECT AIR PRESSURE FROM DRILL UNIT. PUSH DOWN ON PRESSURE
RELIEVING BUTTON ON FILL CAP. REMOVE FILL CAP. USING A SCREW DRIVER, ADJUST LUBRICATOR
TO REQUIRED SETTING. TO INCREASE OIL, SET AT HIGHER NUMBER. TO DECREASE OIL, SET AT LOWER
NUMBER.
Adjust Lubricator Here
Air Supply
Содержание Hornet 24/22
Страница 16: ...Dowel Drill Manual 16 PARTS MANUAL 30 HAMMER...
Страница 17: ...17 Dowel Drill Manual PARTS MANUAL 30 HAMMER...
Страница 18: ...Dowel Drill Manual 18 PARTS MANUAL 50 HAMMER...
Страница 19: ...19 Dowel Drill Manual PARTS MANUAL 50 HAMMER...
Страница 20: ...Dowel Drill Manual 20 PARTS MANUAL...
Страница 21: ...21 Dowel Drill Manual PARTS MANUAL...
Страница 23: ...23 Dowel Drill Manual NOTES...