1.  Remove water purifier from shipping carton. Inspect water purifier, power cord and plug for damage. Do not operate if there 

is any damage to the purifier, power cord or plug. All models, of the 

MINIPURE

®

 

line of water purifiers, are shipped with the 

lamps packed separately. Keep the lamp aside for installation once the purifier has been properly installed.

2.  Units occasionally experience damage in shipment due to the fragility of the quartz sleeve.  It is therefore recommended to 

inspect the water purifier for damage to the quartz sleeve after it has been removed from the shipping carton. Each end of the 
unit as well as the inlet and outlet should be viewed to see if the quartz sleeve has experienced damage. If the quartz sleeve 
shows signs of damage it should be replaced before the purifier is pressurized.  See 

“Quartz Sleeve Installation, Cleaning 

or Replacement”

 in the 

“Maintenance”

 section for the proper method of replacing the quartz sleeve in your water purifier.

3.  The water purifier should be mounted horizontally on a flat dry surface. The purifier should not be solely supported by its 

plumbing connections. Securing the water purifier using the optional wall bracket kit is recommended. 

4.  The water purifier must be connected to the cold water line only. Inlet water temperature should not exceed 100

F.

5.  Installation requires a 5-micron sediment filter be installed, in line, prior to the water purifier. The sediment filter will stop 

or trap large particulates from entering the water purifier. Particulates may cause damage to the quartz sleeve, as well as 
interfere with the purifier’s ability to disinfect the water. The sediment filter may also help to reduce the amount of routine 
cleanings of the quartz sleeve.

6.  Shut off valves should be installed on both the inlet and outlet sides of the water purifier. 

The use of bypass valves is not 

recommended.

 The shut off valves allow the purifier to be isolated from the water supply, which is required when removing 

the quartz sleeve.

7.  Unions should be installed on both the inlet and outlet of the water purifier; this will allow easy removal of the water purifier 

from the plumbing, if required. Apply Teflon

®

 tape to threads of inlet and outlet ports to ensure a tight seal.

8.  When all plumbing connections are complete, allow water to enter the water purifier at a low flow rate, until the purifier is 

full. 

NOTE: Close the purifier outlet valve to pressurize the chamber. 

With the purifier pressurized, it should be checked 

for leaks. Once it is determined that there are no leaks, the inlet valve can be fully opened.

Figure 3 - 120v and 220v 50/60Hz (ballast no. 10-0508B and 10-0504B) 

9.  Unpack the lamp and ballast. While holding lamp end, carefully push lamp socket on. Carefully slide lamp straight into the 

quartz sleeve, without angling. Push the End Cap on, over the static gland nut. Attach the ground connector to the grounding 
stud of the chamber, with included hardware (see steps 1, 2, and 3 on Page 8)

               

 To ensure proper operation and safety of your water purifier, your unit must be grounded  

to a known good ground.

 Lamp and quartz sleeve are easily damaged. Exercise care when handling.

IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY  
EQUIPMENT: SAFETY GOGGLES OR A FACE SHIELD, AS WELL AS GLOVES.

Содержание MIN-6

Страница 1: ...2017 Atlantic Ultraviolet Corporation ASSEMBLED IN THE USA Installation Operation Maintenance Read and Follow All Safety Instructions Save These Instructions Models Ballast 120v 50 60 Hz Ballast 230v 50 60Hz MIN 6 10 0508B 10 0504B MIN 9 10 0508B 10 0504B Owner s Manual Owner s Manual ULTRAVIOLET WATER PURIFIERS ...

Страница 2: ...lieved to be correct However no guarantee or warranty of any kind expressed or implied is made with respect to the information contained herein Specifications and information are subject to change without notice SAFETY WARNINGS 3 SAFETY INSTRUCTIONS 3 SAFETY LABELING 3 CAUTION 3 PRODUCT APPLICATION 4 Construction 4 Principle of Operation 4 Limitation of Use 4 Water Quality 4 INSTALLATION 5 Locatio...

Страница 3: ...ot avoided COULD result in death or serious injury This symbol pictorial is used to identify the need to wear approved ultraviolet blocking eyewear This symbol pictorial is used to identify the need to wear approved ultraviolet blocking face shield This symbol pictorial is used to identify components which must not be disposed of in trash Danger indicates an IMMINENTLY hazardous situation which if...

Страница 4: ...z sleeve and the chamber wall Suspended microorganisms are exposed to the ultraviolet rays emitted by the germicidal lamp The LED indicator light located on the ballast provides visual indication of germicidal lamp operation Water leaving the purifier is instantly ready for use no further contact time is required Limitation of Use The water purifier is intended for the use with visually clear wate...

Страница 5: ...will not result in damage to the area surrounding the water purifier For added protection it is recommended that a suitable drain pan be installed under the purifier The drain pan must be plumbed to an adequate free flowing drain to prevent water damage in event of a leak There are numerous leak detection flood stop devices available on the market today designed to stop flow of water reducing the ...

Страница 6: ...ble 2 MIN 6 and MIN 9 Dimensional Data Model A B C D E F Inlet Outlet MIN 6 14 3 4 22 17 32 5 3 4 4 1 4 22 5 3 8 3 4 m NPT MIN 9 21 7 8 29 17 32 5 3 4 4 1 4 29 5 3 8 3 4 m NPT All specifications dimensional data etc are approximate and subject to change without notice ...

Страница 7: ... entering the water purifier Particulates may cause damage to the quartz sleeve as well as interfere with the purifier s ability to disinfect the water The sediment filter may also help to reduce the amount of routine cleanings of the quartz sleeve 6 Shut off valves should be installed on both the inlet and outlet sides of the water purifier The use of bypass valves is not recommended The shut off...

Страница 8: ... Safety Sensor alerts the user to any malfunction detected 3 PromateTM Time Delay Mechanism Provides a 2 minute warm up period during which the ultraviolet lamp achieves its full germicidal output before the water is allowed to flow through the water purifier The time delay mechanism is used in conjunction with and is electrically connected to the Solenoid Valve 4 PromateTM Solenoid Valve Operated...

Страница 9: ...rovides visual indication of germicidal lamp operation This provides an indication of lamp operation and does not indicate the level of ultraviolet intensity or transmission through the water Ballasts have a built in audio alarm which will indicate lamp failure On purifiers so equipped the SENTRYTM Safety Sensor provides visual indication of ballast and ultraviolet lamp operation 2 To ensure prope...

Страница 10: ...hamber Be sure to withdraw lamp straight out without angling until completely clear of quartz sleeve Lamp and quartz sleeve are easily damaged Exercise care when handling 5 Reinstall lamp in reverse order Germicidal ultraviolet rays are harmful to eyes and skin Do not restore power to water purifier until lamp and both EASY OFFTM End Caps have been properly reinstalled Step 1 Disconnect Power to W...

Страница 11: ...e quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the opposite end with your finger so that it does not drop to the bottom of the chamber as it slides into the chamber 7 Once the quartz sleeve is removed clean with alcohol or a mild non abrasive detergent Stubborn stains usually can be removed with a dilute hydrochloric acid NOTE Follow all manufacturer s instructio...

Страница 12: ... quartz sleeve parallel to the chamber angling the quartz sleeve in any direction could result in the breakage of the quartz sleeve 11 As the quartz sleeve nears the far end of the chamber support the quartz sleeve by inserting your finger through the far end gland fitting and into the quartz sleeve This will minimize the possibility of breaking the quartz sleeve as it passes through the gland fit...

Страница 13: ...amp as it nears its end of life EOL See Lamp Installation or Replacement in the Maintenance section Germicidal lamp not functioning Replace lamp See Lamp Installation or Replacement in the Maintenance section Low input voltage Verify input voltage to purifier Change in water quality Have water tested to confirm that it does not exceed maximum recommended concentration levels for use with this puri...

Страница 14: ...tional WARNINGS 12volt and 24volt Direct Current DC ballasts and units Many Individuals regard ballasts and units powered by 12volt and 24volt Direct Current DC to be relatively benign from a safety standpoint However a DC ballast in order to operate an ultraviolet discharge lamp must produce an output as high as 600volts This voltage is high enough to produce a very serious or even lethal electri...

Страница 15: ... 1 10 0508B 10 0508B 1B SteadfastTM Lamp Socket SureliteTM Ballast 230v 50 60Hz 1 10 0504B 10 0504B 2 Rubber O Ring Static Gland 2 00 1108B 00 1108B 3 STER L RAY Lamp 1 05 1370 R 05 0097A 4 Static Gland Nut 2 25 1492D 25 1492D 5 Teflon Washer 2 25 1235A 25 1235A 6 Rubber O Ring Quartz Sleeve 2 00 1238A 00 1238A 7 CRYSTAL CLEARTM Quartz Sleeve 1 15 1112A 15 1006A3 8 EASY OFFTM End Cap no hole 1 25 ...

Страница 16: ... will be free from defects in material and workmanship for a period of one year from the date of shipment thereof or the product s total rated life whichever first occurs Within the warranty period we shall repair or replace such products which are returned to us with shipping charges prepaid and which are determined by us to be defective This warranty will not apply to any product which has been ...

Отзывы: