TECHNICAL SPECIFICATIONS

Table 4 - Technical Specifications

Model:

MIN-6

MIN-9

Flow Rate (GPM):

6

9

Inlet\Outlet Size:

3/4”m NPT

3/4”m NPT

Number of Lamps:

1

1

Lamp Model No.:

05-1370-R

05-0097A

Length:

22-17/32”

29-17/32”

Width:

4-1/4”

4-1/4”

Height:

5-3/8”

5-3/8”

Chamber Diameter:

4-1/4”

4-1/4”

Shipping Weight:

14 Lbs.

18 Lbs.

Voltage: 

j

120V 50/60Hz

120V 50/60Hz

Power Consumption: 

k

21 Watts

32 Watts

Max Operating Pressure:

100 PSI

100 PSI

Ambient Temperature:

35° F - 100° F

35° F - 100° F

Quartz Sleeve:

1

1

Sentry

TM

 Safety Sensor 

Optional

Optional

Audio Alarm:

Optional

Optional

Time Delay Mechanism:

Optional

Optional

Elapsed Time Indicator, Universal Input

Optional

Optional

Solenoid Valve:

Optional

Optional

Flow Control:

Optional

Optional

WARNINGS

  
                                        12volt and 24volt Direct Current (DC) ballasts and units.

Many Individuals regard ballasts and units powered by 12volt and 24volt Direct Current (DC) to be relatively benign 
from a safety standpoint. However, a DC ballast, in order to operate an ultraviolet discharge lamp, must produce an 
output as high as 600volts. This voltage is high enough to produce a very serious or even lethal electric shock.

IT IS IMPERATIVE

 that all DC ballasts and DC ultraviolet units be wired and grounded appropriately. 

 
 

  Failure to ground all Direct Current (DC) ballasts and/or the equipment it is employed in, can 

 

 result in serious injury or death.

 

j

220V 50Hz, 220V 60Hz, 12V, or 24V DC units are also available. Consult Factory for specific voltage requirements.

 

k

Total power consumption, including ballast loss (based on 120V unit).

All specifications, dimensional data, etc are approximate and subject to change without notice.

Содержание MIN-6

Страница 1: ...2017 Atlantic Ultraviolet Corporation ASSEMBLED IN THE USA Installation Operation Maintenance Read and Follow All Safety Instructions Save These Instructions Models Ballast 120v 50 60 Hz Ballast 230v 50 60Hz MIN 6 10 0508B 10 0504B MIN 9 10 0508B 10 0504B Owner s Manual Owner s Manual ULTRAVIOLET WATER PURIFIERS ...

Страница 2: ...lieved to be correct However no guarantee or warranty of any kind expressed or implied is made with respect to the information contained herein Specifications and information are subject to change without notice SAFETY WARNINGS 3 SAFETY INSTRUCTIONS 3 SAFETY LABELING 3 CAUTION 3 PRODUCT APPLICATION 4 Construction 4 Principle of Operation 4 Limitation of Use 4 Water Quality 4 INSTALLATION 5 Locatio...

Страница 3: ...ot avoided COULD result in death or serious injury This symbol pictorial is used to identify the need to wear approved ultraviolet blocking eyewear This symbol pictorial is used to identify the need to wear approved ultraviolet blocking face shield This symbol pictorial is used to identify components which must not be disposed of in trash Danger indicates an IMMINENTLY hazardous situation which if...

Страница 4: ...z sleeve and the chamber wall Suspended microorganisms are exposed to the ultraviolet rays emitted by the germicidal lamp The LED indicator light located on the ballast provides visual indication of germicidal lamp operation Water leaving the purifier is instantly ready for use no further contact time is required Limitation of Use The water purifier is intended for the use with visually clear wate...

Страница 5: ...will not result in damage to the area surrounding the water purifier For added protection it is recommended that a suitable drain pan be installed under the purifier The drain pan must be plumbed to an adequate free flowing drain to prevent water damage in event of a leak There are numerous leak detection flood stop devices available on the market today designed to stop flow of water reducing the ...

Страница 6: ...ble 2 MIN 6 and MIN 9 Dimensional Data Model A B C D E F Inlet Outlet MIN 6 14 3 4 22 17 32 5 3 4 4 1 4 22 5 3 8 3 4 m NPT MIN 9 21 7 8 29 17 32 5 3 4 4 1 4 29 5 3 8 3 4 m NPT All specifications dimensional data etc are approximate and subject to change without notice ...

Страница 7: ... entering the water purifier Particulates may cause damage to the quartz sleeve as well as interfere with the purifier s ability to disinfect the water The sediment filter may also help to reduce the amount of routine cleanings of the quartz sleeve 6 Shut off valves should be installed on both the inlet and outlet sides of the water purifier The use of bypass valves is not recommended The shut off...

Страница 8: ... Safety Sensor alerts the user to any malfunction detected 3 PromateTM Time Delay Mechanism Provides a 2 minute warm up period during which the ultraviolet lamp achieves its full germicidal output before the water is allowed to flow through the water purifier The time delay mechanism is used in conjunction with and is electrically connected to the Solenoid Valve 4 PromateTM Solenoid Valve Operated...

Страница 9: ...rovides visual indication of germicidal lamp operation This provides an indication of lamp operation and does not indicate the level of ultraviolet intensity or transmission through the water Ballasts have a built in audio alarm which will indicate lamp failure On purifiers so equipped the SENTRYTM Safety Sensor provides visual indication of ballast and ultraviolet lamp operation 2 To ensure prope...

Страница 10: ...hamber Be sure to withdraw lamp straight out without angling until completely clear of quartz sleeve Lamp and quartz sleeve are easily damaged Exercise care when handling 5 Reinstall lamp in reverse order Germicidal ultraviolet rays are harmful to eyes and skin Do not restore power to water purifier until lamp and both EASY OFFTM End Caps have been properly reinstalled Step 1 Disconnect Power to W...

Страница 11: ...e quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the opposite end with your finger so that it does not drop to the bottom of the chamber as it slides into the chamber 7 Once the quartz sleeve is removed clean with alcohol or a mild non abrasive detergent Stubborn stains usually can be removed with a dilute hydrochloric acid NOTE Follow all manufacturer s instructio...

Страница 12: ... quartz sleeve parallel to the chamber angling the quartz sleeve in any direction could result in the breakage of the quartz sleeve 11 As the quartz sleeve nears the far end of the chamber support the quartz sleeve by inserting your finger through the far end gland fitting and into the quartz sleeve This will minimize the possibility of breaking the quartz sleeve as it passes through the gland fit...

Страница 13: ...amp as it nears its end of life EOL See Lamp Installation or Replacement in the Maintenance section Germicidal lamp not functioning Replace lamp See Lamp Installation or Replacement in the Maintenance section Low input voltage Verify input voltage to purifier Change in water quality Have water tested to confirm that it does not exceed maximum recommended concentration levels for use with this puri...

Страница 14: ...tional WARNINGS 12volt and 24volt Direct Current DC ballasts and units Many Individuals regard ballasts and units powered by 12volt and 24volt Direct Current DC to be relatively benign from a safety standpoint However a DC ballast in order to operate an ultraviolet discharge lamp must produce an output as high as 600volts This voltage is high enough to produce a very serious or even lethal electri...

Страница 15: ... 1 10 0508B 10 0508B 1B SteadfastTM Lamp Socket SureliteTM Ballast 230v 50 60Hz 1 10 0504B 10 0504B 2 Rubber O Ring Static Gland 2 00 1108B 00 1108B 3 STER L RAY Lamp 1 05 1370 R 05 0097A 4 Static Gland Nut 2 25 1492D 25 1492D 5 Teflon Washer 2 25 1235A 25 1235A 6 Rubber O Ring Quartz Sleeve 2 00 1238A 00 1238A 7 CRYSTAL CLEARTM Quartz Sleeve 1 15 1112A 15 1006A3 8 EASY OFFTM End Cap no hole 1 25 ...

Страница 16: ... will be free from defects in material and workmanship for a period of one year from the date of shipment thereof or the product s total rated life whichever first occurs Within the warranty period we shall repair or replace such products which are returned to us with shipping charges prepaid and which are determined by us to be defective This warranty will not apply to any product which has been ...

Отзывы: