background image

 

 

 

 

miniDSP Ltd, Hong Kong / 

www.minidsp.com

 / Features and specifications subject to change without prior notice

 

S

AFETY 

I

NSTRUCTIONS

 

 

Read all information for installation, connection, and usage. 

 

Keep this user manual in a safe place during the lifetime of the product. The user manual forms an integral 
part of the product. Reselling of the product is only possible if the user manual is available. Any changes 
made to the product have to be documented in writing and passed on to the buyer in the event of resale. 

 

Heed all warnings. 

 

Follow all instructions. 

 

Do not use this product near water (for example, in damp rooms or near a swimming pool). 

 

Clean only with a dry cloth. 

 

Do not cover the heat sink. Install in accordance with the user manual. 

 

Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that produce 
heat. 

 

Protect the power cord from being walked on, pinched or damaged in any way. Pay particular attention to 
plugs and the point where they exit from the Amplifier Unit. 

 

The product may only be used in accordance with the information provided in the user manual. Before and 
during the usage of the amplifier please ensure that all recommendations, especially the safety 
recommendations as detailed in the user manual, are adhered to. The Amplifier Unit is designed for the 
amplification of pulsed audio signals and the Amplifier Unit should only be connected to speakers with 
average impedance that is not lower than the impedances specified in the User's Manual. 

 

Do not place the product on an unstable cart, stand, tripod, bracket, or table. The device may fall, causing 
serious injury, and serious damage to the device itself. 

 

The Amplifier Unit can only be disconnected from the power supply by removing the plug, which must be 
freely accessible at all times. Unplug this Amplifier Unit during lightning storms or when unused for long 
periods of time. 

 

Refer all servicing to qualified service personnel. 

Damage that requires service 

Unplug the Amplifier Unit from the mains supply and refer to your dealer/distributor or other authorized repair 
workshop. Servicing is required when: 

1.

 

The power-supply cord or plug has been damaged, 

2.

 

Liquid has been spilled or objects have fallen into the amplifier, 

3.

 

The amplifier has been exposed to rain or moisture, 

4.

 

The amplifier has been dropped or suffered damage in any way, 

5.

 

The amplifier exhibits a distinct change from its normal function or performance. 

Содержание PWR-16

Страница 1: ...miniDSP Ltd Hong Kong www minidsp com Features and specifications subject to change without prior notice 1 PWR 16 16 CHANNEL MULTIZONE AUDIO POWER AMPLIFIER User Manual...

Страница 2: ...to change without prior notice 2 Revision history Revision Description Date 0 1 First draft 22 June 2015 0 2 Second draft 20 July 2015 1 0 First release version 6 October 2015 1 1 Updates for control...

Страница 3: ...2 Maximum power capabilities 9 1 3 Typical applications 10 1 3 1 Home theater 10 1 3 2 Multizone audio 10 2 Installation and connectivity 11 2 1 Power 11 2 2 Signal 11 2 2 1 Inputs 11 2 2 2 Outputs 1...

Страница 4: ...tion or alteration of the unit in any way or any usage outside of that recommended in this manual If in doubt contact miniDSP prior to use FCC CLASS B STATEMENT This device complies with Part 15 of th...

Страница 5: ...61000 4 2 2008 IEC 61000 4 4 2012 FCC 47 CFR Part 15 Subpart B ICES 003 Issue 5 2012 ANSI C63 4 2009 A NOTE ON THIS MANUAL This User Manual is designed for reading in both print and on the computer If...

Страница 6: ...ring the usage of the amplifier please ensure that all recommendations especially the safety recommendations as detailed in the user manual are adhered to The Amplifier Unit is designed for the amplif...

Страница 7: ...o EN55103 2 Electromagnetic compatibility Product family standard for audio video and audio visual and entertainment lighting control apparatus for professional use Part 2 Immunity Ventilation and hea...

Страница 8: ...g flashes indicate high voltages that are potentially life threatening Wiring to these terminals requires installation by an instructed person and the use of ready made leads or cords Custom wiring sh...

Страница 9: ...ompact 1U rack enclosure Extremely low weight 400 Watts of audiophile sound quality in eight separate zones for exceptional installation convenience Amplification by ICEpower Low power consumption and...

Страница 10: ...amplification In the scenario shown each speaker can be driven by one channel 4 ohm load single ended mode or by a zone in BTL mode minimum load 6 ohms Please observe the maximum power capability acr...

Страница 11: ...in actual usage the channels can be used in any manner suited to the application Each zone can be used as two independent channels or switched into BTL mode which delivers twice the power into a singl...

Страница 12: ...udspeaker Combined the two channels in a zone can deliver up to 160 Watts peak power into a nominal loudspeaker load of 6 to 8 ohms1 The mode switch must be set to the BTL position as illustrated in t...

Страница 13: ...the outputs or excessive current draw from the speaker load If this LED lights red it indicates that the power supply has either exceeded its thermal limits or there has been excessive current draw f...

Страница 14: ...e not in use are disabled to reduce power consumption and heat dissipation 3 2 2 Control I O connector The 10 pin Phoenix connector on the rear panel carries a comprehensive set of control signal inpu...

Страница 15: ...Trigger IN disconnected Leave Pin 6 3 5V Trigger IN disconnected 3 2 3 2 Signal Sense The PWR 16 can be turned on by sensing an audio signal The signal sense input is connected to Pin 1 with Pin 2 use...

Страница 16: ...ound reference The amplifier will be turned on when the trigger signal is at 12V and off when it is at 0 V Pin 4 is hard wired to Pin 3 and is intended for use as a 12V trigger output To use an extern...

Страница 17: ...in 6 3 5V Trigger IN using Pin 5 Logic Trigger ground as ground reference 3 2 4 Status outputs Pins 7 and 8 provide logic level status output of thermal overload and overcurrent detected These outputs...

Страница 18: ...per zone All zones driven 50W per zone 8 ohms 0 1 THD N 20Hz f 20kHz up to 80 seconds THD N 0 003 4 SE f 100Hz Po 1W Dynamic range 110dBA SE 115dBA BTL Frequency response 0 4 dB 10Hz 20kHz all loads I...