background image

 

 

 

 

miniDSP Ltd, Hong Kong / 

www.minidsp.com

 / Features and specifications subject to change without prior notice

 

Notice

: Changes or modification not expressly approved by the party responsible for compliance could void the 

user’s authority to operate the equipment. 

S

AFETY 

&

 

EMC

 STANDARDS

 

Safety & EMC standards covered: 

UL 60065, 7th edition, 2013-07-24 
CAN/CSA-C22.2 No. 60065-03, 1st E A1: 2006 + A2: 2012 
IEC 60065:2001 (Seventh Edition) + A1: 2005 + A2: 2010 
EN 60065:2002 / A1: 2006 / A11: 2008 / A2: 2010 / A12: 2011 

EMC standards covered are: 

EN 55013: 2001 + A1: 2003 + A2: 2006  
CISPR 13: 2001 + A1: 2003 + A2: 2006  
EN 61000-3-2: 2006 + A1:2009 + A2: 2009  
IEC 61000-3-2: 2005 + A1:2009 + A2: 2009  
EN 61000-3-3: 2013  
IEC 61000-3-3: 2013  
EN 55020: 2007 + A11: 2011  
CISPR 20: 2006  
IEC 61000-4-2: 2008  
IEC 61000-4-4: 2012  
FCC 47 CFR Part 15 Subpart B  
ICES-003 Issue 5-2012  
ANSI C63.4-2009 

A

 

N

OTE ON THIS 

M

ANUAL

 

This User Manual is designed for reading in both print and on the computer. If printing the manual, please print 
double-sided. The embedded page size is 8 ½” x 11”. Printing on A4 paper will result in a slightly reduced size. 

For reading on the computer, we have included hyperlinked cross-references throughout the manual. In 
addition, a table of contents is embedded in the PDF file. Displaying this table of contents will make navigation 
much easier: 

 

In Adobe Reader on Windows, click on the “bookmarks” icon at the left. The table of contents will appear on 
the left and can be unfolded at each level by clicking on the “+” icons. 

 

In Preview on the Mac, click on the 

View

 menu and select 

Table of Contents

. The table of contents will 

appear on the left and can be unfolded at each level by clicking on the triangle icons. 

Содержание PWR-16

Страница 1: ...miniDSP Ltd Hong Kong www minidsp com Features and specifications subject to change without prior notice 1 PWR 16 16 CHANNEL MULTIZONE AUDIO POWER AMPLIFIER User Manual...

Страница 2: ...to change without prior notice 2 Revision history Revision Description Date 0 1 First draft 22 June 2015 0 2 Second draft 20 July 2015 1 0 First release version 6 October 2015 1 1 Updates for control...

Страница 3: ...2 Maximum power capabilities 9 1 3 Typical applications 10 1 3 1 Home theater 10 1 3 2 Multizone audio 10 2 Installation and connectivity 11 2 1 Power 11 2 2 Signal 11 2 2 1 Inputs 11 2 2 2 Outputs 1...

Страница 4: ...tion or alteration of the unit in any way or any usage outside of that recommended in this manual If in doubt contact miniDSP prior to use FCC CLASS B STATEMENT This device complies with Part 15 of th...

Страница 5: ...61000 4 2 2008 IEC 61000 4 4 2012 FCC 47 CFR Part 15 Subpart B ICES 003 Issue 5 2012 ANSI C63 4 2009 A NOTE ON THIS MANUAL This User Manual is designed for reading in both print and on the computer If...

Страница 6: ...ring the usage of the amplifier please ensure that all recommendations especially the safety recommendations as detailed in the user manual are adhered to The Amplifier Unit is designed for the amplif...

Страница 7: ...o EN55103 2 Electromagnetic compatibility Product family standard for audio video and audio visual and entertainment lighting control apparatus for professional use Part 2 Immunity Ventilation and hea...

Страница 8: ...g flashes indicate high voltages that are potentially life threatening Wiring to these terminals requires installation by an instructed person and the use of ready made leads or cords Custom wiring sh...

Страница 9: ...ompact 1U rack enclosure Extremely low weight 400 Watts of audiophile sound quality in eight separate zones for exceptional installation convenience Amplification by ICEpower Low power consumption and...

Страница 10: ...amplification In the scenario shown each speaker can be driven by one channel 4 ohm load single ended mode or by a zone in BTL mode minimum load 6 ohms Please observe the maximum power capability acr...

Страница 11: ...in actual usage the channels can be used in any manner suited to the application Each zone can be used as two independent channels or switched into BTL mode which delivers twice the power into a singl...

Страница 12: ...udspeaker Combined the two channels in a zone can deliver up to 160 Watts peak power into a nominal loudspeaker load of 6 to 8 ohms1 The mode switch must be set to the BTL position as illustrated in t...

Страница 13: ...the outputs or excessive current draw from the speaker load If this LED lights red it indicates that the power supply has either exceeded its thermal limits or there has been excessive current draw f...

Страница 14: ...e not in use are disabled to reduce power consumption and heat dissipation 3 2 2 Control I O connector The 10 pin Phoenix connector on the rear panel carries a comprehensive set of control signal inpu...

Страница 15: ...Trigger IN disconnected Leave Pin 6 3 5V Trigger IN disconnected 3 2 3 2 Signal Sense The PWR 16 can be turned on by sensing an audio signal The signal sense input is connected to Pin 1 with Pin 2 use...

Страница 16: ...ound reference The amplifier will be turned on when the trigger signal is at 12V and off when it is at 0 V Pin 4 is hard wired to Pin 3 and is intended for use as a 12V trigger output To use an extern...

Страница 17: ...in 6 3 5V Trigger IN using Pin 5 Logic Trigger ground as ground reference 3 2 4 Status outputs Pins 7 and 8 provide logic level status output of thermal overload and overcurrent detected These outputs...

Страница 18: ...per zone All zones driven 50W per zone 8 ohms 0 1 THD N 20Hz f 20kHz up to 80 seconds THD N 0 003 4 SE f 100Hz Po 1W Dynamic range 110dBA SE 115dBA BTL Frequency response 0 4 dB 10Hz 20kHz all loads I...

Отзывы: