background image

Page 10

The Minelab Musketeer Advantage

Using Your NiMH Chargers

a) Plug the charger into the socket on the rechargeable battery pack.
b) Plug the charger into the power source and switch on.
c) A red light will appear on the charger, indicating that it has power (car

charger only).

d) A green light will appear on the battery pack during charging.
e) A completely flat battery pack will take approximately 12 - 14 hours to fully

charge.

f)

The green light on the battery pack will fade/dim once it is fully charged.

g) A fully charged NiMH pack will give between 15 and 20 hours detecting

time, depending on the number of targets found.

Figure 8 - Car & mains battery chargers

Instruction Manual

Page 11

The Musketeer Advantage

Controls & Functions

This section gives detailed descriptions of the controls of the 

Musketeer

Advantage

 and their function. Having knowledge of these controls means that

you will be able to achieve the best performance possible with your detector. As
you gain experience with your detector, it may be useful to refer back to this
section.

Figure 9 - The Musketeer Advantage control panel

Sensitivity Control and On / Off Switch

This knob is located in the middle left-hand side of the
control box and allows the unit to be turned on and off as
well as controlling the sensitivity. This control is often
thought of in terms of a depth control and it is to a point,
but it can also be used to make the unit more stable if
interference caused by ground chemistry “mineralization”
or electrical fields is experienced.

At its Maximum position, the detector may be noisy depending on electrical
interference and ground mineralization. To get the best depth from your
detector, this control should be set as high as you feel comfortable. If you can
operate with some noise, then you are likely to get more depth. If you prefer
your detector to run quietly, then turn the Sensitivity down until it is “just” quiet.
It’s your choice!!

Sensitivity

Ground Adjust

Enable

Threshold Reset

Pinpoint

All Metals

Discriminate

Ground Adjust

Level Adjust

Off

Fix

Advantage

P0556-A

Содержание Musketeer ADVANTAGE

Страница 1: ...ur Musketeer Advantage 5 Batteries 8 The Musketeer Advantage 11 Controls Functions 11 Basic Operating Instructions 18 Practicing the Controls 19 Treasure Hunting Tips 21 Environmental Concerns 22 Dete...

Страница 2: ...hunter Units may be moved at a rapid hunt pace or at a much more leisurely pace while enjoying the sharp target response in either mode without sacrificing depth capabilities You will be surprised at...

Страница 3: ...s in design equipment and technical features at any time Instruction Manual Page 5 Accessories To further enhance your Advantage and give you greater capacity and versatility the following items are a...

Страница 4: ...a Position the control box so that the recess in the control box 11 is aligned with the leading edge of the mounting clip 12 Push the foward section of the control box upwards until the trigger clicks...

Страница 5: ...osition to securely hold your battery pack in place Fig 7 CAUTION High quality alkaline batteries should be used instead of standard carbon batteries as they will power your Advantage longer The use o...

Страница 6: ...ce possible with your detector As you gain experience with your detector it may be useful to refer back to this section Figure 9 The Musketeer Advantage control panel Sensitivity Control and On Off Sw...

Страница 7: ...en reduce the level of sensitivity to compensate for the excess mineralization Instruction Manual Page 13 Discriminate All Metals Switch The Discriminate All metals mode switch is located in the lower...

Страница 8: ...dig old bottle caps but want to dig brass buttons or copper coins the Discrimination LevelAdjust control is set higher approximately at number 7 in Figure 10 but most fine white gold rings foil and so...

Страница 9: ...to move the coil closer to the taget and further refine your search Instruction Manual Page 17 After you have pinpointed and retrieved the target the Sensitivity of the detector should be reset to nor...

Страница 10: ...vices or metal objects and support the Musketeer so that objects can be easily moved past the coil Then a Ensure the Mode Switch is in Discriminate b Turn the Discriminate control to approx 1 position...

Страница 11: ...some later time to improve your knowledge of how your Advantage performs As you become more experienced in using the Advantage you will notice that your trash ratio will drop even though you may not...

Страница 12: ...finely engineered and packaged in a durable housing Taking proper care of it is mostly common sense Do not leave batteries in the control box when the detector is not in use for a period exceeding two...

Страница 13: ...rm on page 27 and enclose it with the detector Please supply as much detail as possible about the fault as this will assist our service engineers to rectify the problem quickly and efficiently Instruc...

Страница 14: ...t regulations or environmental requirements Please dispose of this equipment via a recycling service or centre or by returning the unit to the respective Minelab or Halcro outlet as appropriate for yo...

Отзывы: