14
⑥
Brand number (4 stations)
It is area which showing the Brand number.
Data type
: 8 bit binary
⑦
General data area (4 stations, 2 stations)
When the set value reading out command is ordered by using the general command request
(Request 2), this area represents the set value.
Data type
: 32 bit binary with sign
⑧
Command No.
(Response) (4 stations, 2 stations)
When the command order is executed by the general command request (Request 2), this area
represents that command No.
Data type
: 8 bit binary
⑨
Operation mode (Response) (4 stations, 2 stations)
When the operation mode is changed by the operation mode changeover request (request 3), this
area represents that command No.
This function is prepared for future expansion.
Data type
: 8 bit binary
⑩
Indicate value (Net value/Gross value) (2 stations, 1 station)
It is area which showing the Net value or Gross value by specified bit.
Data type
: 32 bit binary with sign
Setting range :
-999999
~
999999