4.4 Fitting the reduction sealing ring
Note:
It is essential to irst insert the side with the sealing lip in the metal sleeve!
1. Unscrew the cap nuts (2).
2. Remove the existing sealing ring from the metal sleeve (3).
3. Insert the reduction sealing ring (1) in the M20 cable gland (for cables ≤8 mm).
4. Tighten the cap nuts (2) again.
4 Installation and connection information
Cable Junction Box PR 6130/38S
Minebea Intec
EN-13