Protection classes
in compliance with EN 60529
IP68/IP69:
Dust-proof and leak-tight against water, with harmful efects when immersed, (1.5 m
water depth, 10,000 h) and water jets (high pressure and temperature).
Explosion:
Suitable for explosion subgroup IIC and IIIC.
Protection type
Intrinsic safety for Inteco®/..E
Ambient temperature in
the Ex area
see additional information “safety instructions for Ex load cells”
Cable diameter
5 mm
Cable gauge
4×0.35 mm
2
Cable bend radius
≥25 mm (ixed installation)
≥75 mm (lexible installation)
Cable sheath material
Thermoplastic elastomer (TPE)
Cable sheath color
Gray (standard version)
Blue (Ex version)
4.3 Possible marking of the load cell for the Ex area
Zone
Marking
Certiicate no.
for
0 and 1
II 1G Ex ia IIC T6 Ga
Ex ia IIC T6 Ga
BVS 17 ATEX E 111X
IECEx BVS 17.0092X
only Inteco®/..E
20 and 21
II 1D Ex ta IIIC T160 °C Da
Ex ta IIIC T160 °C Da
TÜV 03 ATEX 2301X
IECEx TUN 17.0025X
all Inteco® without
/..E
2
II 3G Ex nA IIC T6 Gc
MIN16ATEX001X
all Inteco® without
/..E
22
II 3D Ex tc IIIC T85 °C Dc
MIN16ATEX001X
all Inteco® without
/..E
IS CL I, II, III, DIV 1, GP A, B, C, D, E, F, G Enti-
ty - 4012 101 5688
NI CL I, II, III, DIV 2, GP A, B, C, D, E, F, G -
4012 101 5688; NIFW
T4A Ta= -40°C to 70°C; T5 Ta= -40°C to
55°C
FM17US0276
all Inteco® without
/..E
IS CL I, II, III, DIV 1, GP A, B, C, D, E, F, G Enti-
ty - 4012 101 5688
NI CL I, II, III, DIV 2, GP A, B, C, D, E, F, G -
4012 101 5688; NIFW
T4A Ta= -40°C to 70°C; T5 Ta= -40°C to
55°C
FM17CA0138
all Inteco® without
/..E
Compression load cell Inteco® PR 6203
4 Speciications
EN-10