Operating Instructions Combics 3 Filling
23
Accessing Application-specific Information
You can access all application-specific parameters and the contents of the
totalizing memory.
Example:
Accessing and printing application-specific information
t
Press and hold the
D
key to load the information display.
t
Press the
p
key to print the information display.
Additive Filling 01
Memory name (only option H4)
Granulate red
Product info
Target + 2.500 kg
Target value
Tol- + 0.100 kg
Tolerance -
Tol+ + 0.200 kg
Tol
Sh.C.+ 1.000 kg
Coarse flow shutoff point
Sh.F. + 0.200 kg
Fine flow shutoff point
StartC 1
Value for start of series (if configured)
StopC 2
Value for end of series (if configured)
--------------------
Operation