background image

PANEL DESCRIPTION

3 ½ Digit LED Display

Switch (OUT1)  

Setting 

B

utton

Green LED

Display the measured

pressure value. each setting

mode and error code.

(    ) Button

Change setting mode and 

pre-set final desired value.

Switch(OUT 2)

Red LED

Use the(    ) button to change 

setting mode and pre-set 

desired value.

OUTPUT CIRCUIT WIRING DIAGRAMS

For your safety, please read the following before using.

Do not use corrosive or flammable gas or liquid with this product.
Please use within the operating pressure range. Do not apply pressure beyond recommended maximum pressure,  permanent 

damage to the pressure sensor may occur. 
Do not drop, hit or allow excessive shock. Even if switch body appears undamaged, internal components may be broken and 

can cause malfunction.
Turn power off before connecting wiring. Wrong wiring or short circuit will damage and/or cause malfunction. 
Do not use in environment containing steam or oil vapor.
This product is not explosion-proof rated. Do not use in atmosphere containing flammable or explosive gases.
Wiring for pressure sensor should avoid power source line and high voltage line. If use in the same circuit, noise may cause 

malfunction.

ORDERING INFORMATION

Use the(    ) button to change 

setting mode and pre-set 

desired value.

-100.0 ~ 100.0kPa

0.0 ~ -101.3kPa

-0.100 ~ 1.000MPa

10.0 ~ -101.3kPa

0.000 ~ 1.000MPa

0.1

0.001
0.001

0

.01

-

0.001

0

.01

0

.01

0.1

-
-

-

1

0.1

0.1

Filtered 

Air, Non-corrosive/Non-flammable  gases

12 to 24V DC ±10%, Ripple (P-P) 10% or less

 60mA 

±0.2% F.S. ±1digit 

Fixed (3 digits)

 2.5ms (chattering-proof  function: 24ms, 192ms and 768ms selections)

Yes

3 ½ digit, 7 segment LED display ( Red ) ( Sampling rate : 5 times / sec. )

±2% F.S. ±1 digit  (Ambient temperature: 25 ±3°C)

Green Indicator : OUT1 & Red Indicator : OUT2

-100.0 ~ 100.0kPa

(Vacuum)

(Positive)

(Compound)

Operation/Storage: 35 ~ 85% RH (No condensation)

1000V AC in 1-min (between case and lead wire) 

IP40

50M

Ω

 (at 500V DC, between case and lead wire) 

980m/s

(100G), 3 times each in direction of X, Y and Z

±2% F.S. of detected pressure (25°C) at temp. Range of 0~50°C

Ø4 Oil-resistance cable ( PVC ) - 26 AWG ( 0.15 mm

2

 ) - 5 cores ( MP30 □ - 01 / 03 ) ;

Ø4 Oil-resistance cable ( PVC ) - 26 AWG ( 0.15 mm

2

 ) - 4 cores ( MP30 □ - 02 / 04 )

Operation: 0 ~ 50°C, Storage: -20 ~ 60°C (No condensation or freezing)

Approx. 67g (with 2 meter lead wire), Approx. 35g (with M8 4Pin male connector )

Total amplitude 1.5mm, 10Hz-55Hz-10Hz scan for 1 minute, two hours each direction of X, Y and Z

Adjustable

300kPa

1.5MPa

Output voltage: 1 to 5V ±2.5% F.S.

(within rated pressure range)

Linearity: ±1% F.S. 

Output voltage: 1 to 5V 

±

5%

 

F.S. 

 (within rated pressure range)

Linearity: ±

1

% F.S. 

Pressure Range

Output Specifications

C

Compound (-100.0~100.0kPa)

V

Vacuum (10.0~-101.3kPa)

P

Positive (-0.100~1.000MPa)

F1

R1/8", M5

F2

NPT1/8", M5

F3

G1/8”(BSPP), M5

Blank

With 2meter cable

QD

With M8 4Pin male connector

*(Only type MP30 

 

   -02- 

    

, MP30 

 

   -04- 

    )

 

 

01

2 NPN output & 1 Analog output

02

2 NPN output

03

2 PNP output & 1 Analog output

04

2 PNP output

Cable Length/Connector

Pressure Port

MP30    - 02-    -    

NPN output

MP30    - 01-    -     

NPN output & Analog output

S

wit

ch

 m

ain

 cir

cuit

S

wit

ch

 m

ain

 cir

cuit

S

wit

ch

 m

ain

 cir

cuit

S

wit

ch

 m

ain

 cir

cuit

DC(–) (Blue)

DC(–) (Blue)

DC(–) (Blue)

DC(–) (Blue)

OUT2 (White)

OUT2 (White)

OUT2 (White)

OUT2 (White)

OUT1 (Black)

OUT1 (Black)

OUT1 (Black)

OUT1 (Black)

(Orange)

(Orange)

Analog Output

Analog Output

DC(+) (Brown)

DC(+) (Brown)

DC(+) (Brown)

DC(+) (Brown)

DC

DC

12-24V

DC

12-24V

DC

12-24V

DC

12-24V

1KΩ

MP30    - 04-    -    

PNP output

MP30    - 03-    -       

PNP output & Analog output

1KΩ

F1:R1/8", M5

F2:

N

PT1/8", M5

F3: G1/8”(BSPP), M5 

F1:R1/8", M5 ; F2:

N

PT1/8", M5 ; F3: G1/8”(BSPP), M5

NPN: open collector 2 outputs 

Max. load current: 100mA

Max. supply voltage: 30V DC 

Residual voltage: 

≦ 

1V  

PNP: open collector 2 outputs 

Max. load current: 100mA

Max. supply voltage: 24V DC

Residual voltage: 

 1V 

MP30C-    -

MP30V-    -

MP30P-    -

R

L

R

L

R

L

R

L

DIMENSIONS

ANALOG OUTPUT

Analog output range 1 to 5V, proportional to the pressure range.

(Compound)
Analog output (V)

5
3

1

-100.0

0.0

100.0 (kPa)

(Low)

(High)

(    ) Button

1

2

3

4

5
6
7

Unit:mm

Rated pressure range
Setting pressure range
Withstand pressure
Fluid

Power supply voltage
Current consumption

Switch output

Hysteresis mode

Response time 
Output short circuit protection
Display
Indicator accuracy
Indicator

kPa
MPa
kgf/cm

2

bar
psi

mm

H

g

inH

g

mmH

2

O

Set pressure

resolution

SPECIFICATIONS

Repeatability(Switch output) 

Hysteresis

Window comparator mode

Ambient temp. range
Ambient humidity range
Withstand voltage

Enclosure

Insulation resistance
Vibration
Shock

Temperature characteristic
Port size

Lead wire

Weight

Environment

Analog output 

*(Only type MP30

 

    -01-  

   , 

MP30

 

    -03- 

    )

 

3

1

4

2

QD PINOUT

PR-0069D    2021/07 Printing      We reserve the right to change the specification without prior notice.

R

L

R

L

R

L

R

L

(Vacuum)
Analog output (V)

5

1

0.0

-101.3 (kPa)

(Low)

(High)

(Positive)
Analog output (V)

5

1

0.000

1.000 (MPa)

(Low)

(High)

300

2000

-

MP30

MINDMAN INDUSTRIAL CO., LTD.

M P 3 0 C - 0 1 - F 1 -

www.mindman.com.tw

Отзывы: