1
1 Technical specifications
Handheld unit
Working range
Up to 200 meters
1
(open air)
Radio link
430.5
~
432.0MHz , 433.05
~
434.79MHz with adaptive frequency hopping
Dimensions
Length × Width × Depth: 17.0 × 7.0 × 8.3 cm
Weight
201 g
Color
Gray
Case material
ABS+TPU
Exit window material
Tempered optical glass
Indicator
LED, Beeper
Input voltage
4.75V – 6.5 V DC
Operating current
12mA (standby); 90mA (scanning); 150mA (transmitting)
Battery
1400 mAh Lithium-ion battery
Charge time
Fully charged (>80%) in 3.5 hours
Standby time
Over 7 days
Read barcode per charge
Over 160,000 scans per charge
Light source
650 nm visible laser diode
Decoding rate
200 times/sec
Scanning angle
±60°, ±65°, ±42° (Skew, Pitch, Roll)
Print contrast
25% minimum reflection difference
Decode capability
UPC-A, UPC-E, UPC-E1, EAN-13, EAN-8, ISBN (Bookland EAN), ISSN,
Code 39, Code 39 full ASCII, Code 32, Trioptic Code 39, Interleaved 2 of 5,
Industrial 2 of 5, Matrix 2 of 5, Codabar (NW7), Code 128, UCC/EAN 128,
ISBT 128, Code 93, Code 11 (USD-8), MSI/Plessey, UK/Plessey, China Post,
China Finance, Telepen, GS1 DataBar (formerly RSS) variants
Decoding depth
& Min. element width
(1 mil = 0.0254mm)
Long-Range series
5 mil: 40-110mm
10 mil: 10-280mm
13 mil: 15-315mm
16 mil: 25-385mm
35 mil: 145-630mm
High-Density series
3 mil: 5-50mm
10 mil: 10-85mm
13 mil: 10-150mm
16 mil: 25-165mm
35 mil: 145-295mm
Temperature
0° to 50°C (32° to 120°F), Operating; -40° to 60°C (-40° to 140°F), Storage
Humidity
5% to 95% (non-condensing)
Operating mode
Handheld
Programming method
Manual (reading special barcode)
Program upgrade
Using RSM software, while a cradle unit is required. Refer to RSM user
manual.
Safety
Laser safety: EN60825-1, Class 1
EMC: EN 55022, EN 55024
Electrical safety: EN 60950-1
Drop resistance: Multiple 1.2m (3.9ft) drops to concrete
Содержание CS3290
Страница 1: ...CS3290 Cordless Barcode Scanner User Manual Version CS3290_UM_EN_V1 2 15...
Страница 2: ......
Страница 4: ...ii location the better...
Страница 10: ...viii...
Страница 17: ...5 4 Decode zone Figure 4 1 High density series Figure 4 2 Long range series...
Страница 18: ...6 5 Dimensions...
Страница 96: ...84 18 Configuration alphanumeric entry barcode To finish parameter setting please scan the bar code below...