29
Calibration
MINIMUM SPEED (MIN SPD)
The MIN SPD trimpot setting determines the motor speed
when the speed adjust potentiometer is turned full CCW. It is
factory set to zero speed.
The minimum speed feature
applies only when the drive is operating in unidirectional
mode.
To calibrate, set the speed adjust potentiometer full CCW.
Adjust the MIN SPD trimpot until the motor turns at the
desired minimum speed.
MAXIMUM SPEED (MAX SPD)
The MAX SPD setting determines the maximum motor speed
when the speed adjust potentiometer is turned full CW. It is
factory set for maximum rated motor speed.
To calibrate, set the speed adjust potentiometer full CW.
Adjust the MAX SPD trimpot until the motor turns at the
desired maximum speed.