32
Calibration
FWD SIG ADJ (-PCM models)
The FWD SIG ADJ setting determines the speed that the motor will
achieve when the signal is at its maximum voltage. For
MMRG30U-PCM and MMRG31U-PCM, it is factory-set to deliver a
90 VDC armature output with a 10 VDC input signal. For
MMRG40U-PCM, it is factory-set to deliver a 180 VDC armature
output with a 10 VDC input signal.
Adjust the FWD SIG ADJ trimpot when the motor is set to run in
forward direction. To change this setting, apply the maximum
voltage signal and rotate the FWD SIG ADJ trimpot until the
desired motor speed is reached.
REV SIG ADJ (-PCM models)
The REV SIG ADJ setting determines the speed that the motor will
achieve when the signal is at its maximum voltage. For
MMRG30U-PCM and MMRG31U-PCM, it is factory-set to deliver a
90 VDC armature output with a -10 VDC input signal. For
MMRG40U-PCM, it is factory-set to deliver a 180 VDC armature
output with a -10 VDC input signal.
Adjust the REV SIG ADJ trimpot when the motor is set to run in
reverse direction. To change this setting, apply the maximum
voltage signal and rotate the REV SIG ADJ trimpot until the desired
motor speed is reached.