9
ASSEMBLY INSTRUCTIONS
6
6. Connect hose and regulator to cylinder.
The LPG gas and cylinder are sold separately.
Use a standard 20 lb. LPG cylinder only
(approximately 12.2 in. / 31cm. in diameter and 17.9 in.
/ 45.5cm high).
Use this heater only with a LPG vapor withdrawal
supply system. See chapter 5 of the standard for
storage and handling of liquefied petroleum gas,
ANS/NFPA 58. Your local library or fire department
should have this book.
Storage of an appliance indoors is permissible only if
the cylinder is disconnected and removed from the
appliance. A cylinder must be stored outdoors in a
well-ventilated area out of the reach of children.
A disconnected cylinder must have dust caps tightly
installed and must not be stored in a building, garage or
any other enclosed area. The maximum inlet gas supply
pressure: 250 psi /1750 kPa. The minimum inlet gas
supply pressure: 5 psi /35kPa. Manifold pressure with
regulator provided: 11 inch W.C/ 2.74 kPa.
The pressure regulator and hose assembly supplied with
the appliance must be used. The installation must conform
with local codes, or in the absence of local codes, with
national fuel gas code, ANS Z223.1/NFPA54, natural gas
and propane Installation Code, CSA B149.1, or propane
storage and handling code, B149.2.
Standard 20 lb. tank
12.2 in. / 31cm
17.9 in. / 45.5cm