Ver 0.1 (6/21) PAGE 13 OF 30
©
Mimo Monitors
Second Concept
– Using existing CAT5e to create a
Point to Point connection in Conference space
This installation method will not require new cabling to be laid, but will consume the existing cabling
and the Myst and Link will not be on the network. No other wired network devices may share the
cabling.
Requirements
-
This installation assumes that there is an existing Network connection near the Myst and the
Link
-
The run from the network termination point (IT closet) is less than 50m
-
This concept is extensible to as many Myst/Link pairs as exist in the closet without limit.
Installation Concept
Same as figure 1, except rather than a dedicated wire through the conference room, you connect
them together back in IT closet
Myst Display and Link Wrapped back to each other
Figure 2:
Network Setup
Find where the Myst Display and Link terminate in local IT closet using network tone and probe tool,
or other method. Remove connection from patch panel to network in both locations. Install new
cable between the 2 termination points. Proceed with setup identical to “Basic Concept”