© 2011 MIMAKI ENGINEERING CO.,LTD.
5.1.26
P.1
R.1.0
5.1.26 LINEAR ENCODER
Function
Linear encoder scale and linear sensor are tested.
Move a carriage by the designated distance (3 reciprocations) to display the difference between linear encoder value
and Y-axis motor encoder value. If an error arises during the operation, discontinue the test.
Moving distance: 100 mm – Maximum actual operation limit (unit: 100 mm)
LCD display is as follows: (M*: Y-axis motor encoder, E*: linear encoder)
• Moving distance
: M=****.* E=****.* (unit: 0.1 mm)
• Difference in encoder values between before and after moving
: Mc=****.* Ec=****.* (unit: 0.1 mm)
• Encoder values before movement
: Ms=***** Es=*****
• Encoder values after movement
: Mm=***** Em=*****
• Encoder values after having moved by designated distance
: Mr=***** Er=*****
Be careful about the carriage which moves in high speed to execute the scan.
MAINTENANCE MANUAL > Test Items > Test Function > LINEAR ENCODER
Model
TS34-1800A
Issued 2011.10.17 Revised
F/W ver
1.20