© 2011 MIMAKI ENGINEERING CO.,LTD.
5.1.10
P.1
R.1.0
5.1.10 [MOTOR TEST] PUMP MOTOR
Function
Operation test of pump motor is executed.
Operation Procedures
Step
Item
Description
Remarks
1
Pump selection
[
], [
] : Selects pump by moving the cursor.
[
], [
] : Selects operation.
[
], [
] :
Selection of items 1 – 3
2
Rotation direction
designation
[
], [
] : Selects pump rotation direction.
Set value: FORWARD, REVERSE
3
Driving speed designation
[
], [
] : Selects driving speed.
Set value: 100 – 4000 pps (unit: 100 pps)
4
Carriage
/Motor state selection
[FUNCTION]:Carriage/motor state at test selection menu is
displayed.
<Carriage> IN: Executes at cap position.
OUT: Executes after carriage out.
<MOTOR> ON: Executes with Y-axis motor ON.
OFF: Executes with Y-axis motor OFF.
5
Test start
[ENTER]: Removes the cap and moves the carriage to
maintenance position. Drives the pump motor with
designated conditions.
[END]: Ends the test.
During operation, open/
close the cartridge valve
with [FUNCTION].
6
End
Test is completed.
Note that executing (FORWARD) while the cap is on causes vacuum suction.
MAINTENANCE MANUAL > Test Items > Test Function > [MOTOR TEST] PUMP MOTOR
Model
TS34-1800A
Issued 2011.10.17 Revised
F/W ver
1.20
Remark
1.0