— 2.43 —
Sample F
The cutter rotates clockwise (or counterclockwise) and the point from which the cutter starts is this
side (or far side) of the predetermined start position.
Corrective measure
Refer to the corrective measures for the
samples B and C.
Sample G
The pattern is finished with rotated clockwise (or counterclockwise) and the tangential cutter shifts
to the right (or left) from the correct position.
Corrective measure
Refer to the corrective measures for the
samples B and E.
Sample H
The point from which the cutter starts is this side (or far side) of the predetermined start position,
and the tangential cutter shifts to the right (or left) from the correct position.
Corrective measure
Refer to the corrective measures for the
samples C and E.