6
Resistance
1. Set the dial to position.
2. Connect the red test lead to the
VΩ terminal and the black test
lead to the COM terminal.
Confirm “OL” is indicated on the
display, and then touch the tips
of the test leads together to short
circuit them to confirm the zero
indication and to ensure the meter
is working normally.
3. Connect the test leads to
both ends of the resistor
under test.
4. The reading is displayed.
cauTion
After shorting the test leads,
the displayed value may not be zero due to the
resistance of test leads themselves.
Continuity
1. Set the dial to position.
2. Connect the red test lead
to the VΩ terminal and the
black test lead to the COM
terminal.
Confirm “OL” is indicated on
the display, and then touch
the tips of the test leads
together to short circuit them
to confirm the zero indication
(may not be zero due to the
resistance of the test leads
themselves) with a buzzer
sound to ensure the meter is
working normally.
3. Connect the test leads to
both ends of the conductor
under test. If the resistance under test is 30 Ω
or less, the buzzer will sound.
Capacitance
1. Set the dial to
position.
2. Connect the red test lead to the
VΩ terminal and the black test
lead to the COM terminal.
3. Discharge capacitor.
4. Connect the test leads to
both ends of the capacitor under
test.
5. The reading is displayed.
AC Current
danger
To reduce the risk of
electric shock for Resistance, Continuity,
and Capacitance measurements, never use
the Digital Multimeter on an energized circuit.
Make sure a capacitor is fully discharged
before touching or attempting to make a
measurement.
Do not use with the battery cover removed.
Hz
Frequency
1. Set the dial to
Hz
position.
2. Connect the red test lead to the
VΩ terminal and the black test
lead to the COM terminal.
3. Connect the test leads to the
circuit under test. The reading
is displayed.
Resistance/Continuity/Capacitance
Measurements
danger
To avoid electrical shock:
Never make measurement on a circuit in
which voltage over 600 volts AC exists.
Do not use with the battery cover removed.
Keep fingers behind the guards and away
from test lead tips during measurements.
1. Set the dial to position.
2. Connect the red test lead to the A terminal and
the black test lead to the COM terminal.
3. Turn circuit power off, disconnect
the circuit, connect the test leads
in series with the circuit under
test, and then turn circuit power
on. The reading is displayed.
0
0
kHz
0
Red
Black
Disconnect
I
0
AC
A
0
0
►60
0
0
►60