![Milwaukee 2216-40 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/milwaukee/2216-40/2216-40_operators-manual_1799008004.webp)
4
symbology
Underwriters Laboratories, Inc.,
United States and Canada
European Conformity Mark
Australia-New Zealand
Certification Mark
1
Canadian Conformity Mark
Cat III
Classification of transient
overvoltages, based on nominal
line voltage to earth.
Fuse
Do not dispose of this product as
unsorted municipal waste.
Read Operator’s Manual
Double Insulation
Risk of Electric Shock
Earth (Ground)
Danger, Warning, or Caution -
Consult the operators manual for
additional safety information.
Battery
Dial Position
Range
Resolution
Accuracy
Voltage AC
6mV-600mV/6V/
60V/600V
0.1mV/0.001V/
0.01V/0.1V
±(1.0% + 3 dgt) (45~500Hz)
±(2.0% + 3 dgt) (500~1000Hz)
Voltage DC
600mV/6V/
60/600V
0.1mV/0.001V/
0.01V/0.1V
±(0.5% + 2 dgt)
Hz
Hertz
2Hz-99.99Hz/999.9Hz/
9.999kHz/50kHz
0.01Hz/0.1Hz/
0.001kHz/0.01kHz
±(0.1% + 2 dgt)
Sensitivity: 10Vp-p
Resistance
600Ω/6kΩ/60kΩ/
600kΩ/6MΩ
0.1/0.001k/0.01k/
0.1k/0.001MΩ
±(1.0% + 5 dgt)
±(1.0% + 5 dgt)
40MΩ
0.01MΩ
±(2.0% + 5 dgt)
Continuity
Cont Buzzer
0-600.0Ω
0.1 Ω
Beeper sounds at 30 Ω and below
Capacitance
100μF / 1000μF
0.1μF / 1μF
±(1.9% + 2 dgt)
Current AC
0.04A - 6A / 10A
0.001A/0.01A
±(1.5% + 3 dgt) (45~500Hz)
Current DC
6A/10A
0.001A/0.01A
±(1.0% + 3 dgt)
functions
* This is a True-RMS instrument. All AC voltage and
AC current readings are True-RMS values.
* Input impedance: Voltage DC: 10MΩ; Voltage AC:
10MΩ // less than 100pF
* Overload protection:
Voltage DC, Voltage AC, and Hertz: AC/DC 720V for
10 second
Current DC & Current AC: AC/DC 20A for 10 sec.
Resistance, Continuity, and Capacitance: AC/
DC 600V for 10 second
* Maximum measurement time: 1 minute at 10A, rest
time 20 minutes minimum
* Minimum fr
e
quency measurement is 2Hz
* Minimum AC Current measurement is 0.040A
* For AC Voltage, and AC Current:
Additional Accuracy by Crest Factor (C.F.):
Add
6.0% for C.F. 1.0 ~ 2.0
Add 7.0% for C.F. 2.0 ~ 2.5
Add 9.0% for C.F. 2.5 ~ 3.0
Max. Crest Factor: 1.6 for 6600 ~ 5000 digits
2.0 for 5000 ~ 3000 digits
3.0 for 3000 ~ 0 digits
* Measurement accuracy of square wave and trun
-
cated waveforms at 1kHz is unspecified.