background image

OPERATOR'S MANUAL

DIgITAL MULTIMETER

 

Cat. No.
2216-

4

0

TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND OPERATOR'S 

MANUAL.

Содержание 2216-40

Страница 1: ...OPERATOR S MANUAL DIgITAL MULTIMETER Cat No 2216 40 TO REDUCE THE RISK OF INJURY USER MUST READ AND UNDERSTAND OPERATOR S MANUAL ...

Страница 2: ...ement Do not ground yourself while measuring Avoid body contact with earthed or grounded sur faces such as pipes radiators ranges and refrigerators This instrument is to be used only in its intended applications or conditions Otherwise the instrument s safety functions may not work resulting in serious personal injury and instru ment damage To reduce the risk of injury from shock and arc blasts al...

Страница 3: ...om the battery avoid contact If contact accidentally occurs flush with water If liquid contacts eyes additionally seek medical help Liquid ejected from the battery may cause irritation or burns Accuracy is specified for 1 year after calibration at operating temperatures of 14 F to 122 F 10 C to 50 C with relative humidity less than 85 Maximum voltage between any terminal and earth ground 600 V Tem...

Страница 4: ...5 dgt 1 0 5 dgt 40MΩ 0 01MΩ 2 0 5 dgt Continuity Cont Buzzer 0 600 0Ω 0 1 Ω Beeper sounds at 30 Ω and below Capacitance 100μF 1000μF 0 1μF 1μF 1 9 2 dgt Current AC 0 04A 6A 10A 0 001A 0 01A 1 5 3 dgt 45 500Hz Current DC 6A 10A 0 001A 0 01A 1 0 3 dgt functions This is a True RMS instrument All AC voltage and AC current readings are True RMS values Input impedance Voltage DC 10MΩ Voltage AC 10MΩ les...

Страница 5: ...exists Do not use with the battery cover removed Keep fingers behind the guards and away from test lead tips during measurements cauTion Readings may fluctuate or be influenced in noisy environment 1 Set the dial to position 2 Connect the red test lead to the VΩ terminal and the black test lead to the COM terminal 3 Connect the test leads to the circuit under test The reading is displayed 1 Set th...

Страница 6: ... red test lead to the VΩ terminal and the black test lead to the COM terminal 3 Discharge capacitor 4 Connect the test leads to both ends of the capacitor under test 5 The reading is displayed AC Current danger To reduce the risk of electric shock for Resistance Continuity and Capacitance measurements never use the Digital Multimeter on an energized circuit Make sure a capacitor is fully discharge...

Страница 7: ...When you turn the Digital Multimeter on it defaults to Autorange and AUTO is displayed To enter the Manual Range mode press RANGE button AUTO disappears In the Manual Range mode press RANGE button to increment the range After the highest range the Meter wraps to the lowest range To exit Manual Range press RANGE button for two seconds or change the dial The Meter returns to Autorange and AUTO is di...

Страница 8: ...NCE OF ANY DAMAGE TO FAILURE OF OR DEFECT IN ANY PRODUCT INCLUDING BUT NOT LIMITED TO ANY CLAIMS FOR LOSS OF PROFITS THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES OR CONDITIONS WRITTEN OR ORAL EXPRESSED OR IMPLIED WITHOUT LIMITING THE GENERALITY OF THE FOREGOING MILWAUKEE DISCLAIMS ANY IM PLIED WARRANTY OF MERCHANTABILITY OR FITNESS FORAPARTICULAR USE OR PURPOSE AND ALL OTHER WARR...

Отзывы: