Pellerin Milnor Corporation
Figure 1. Vibration Switch
Legend
A...
Eccentric weight (adjusts up and
down)
B...
Mounting bracket
C...
Actuating arm
D...
Microswitch (adjusts side to side)
For machines with rigid mounted shells, where the machine is bolted to a very substantial founda-
tion, very little machine movement will occur for a given degree of out-of-balance. Under such
conditions it may be better to adjust the switch to be very sensitive. With less substantial founda-
tions (e.g., ones where the sub-soil is mushy or springy or otherwise not as desirable), consider-
ably greater machine movement will occur for a given degree of out-of-balance, in which case a
less sensitive
vibration switch
setting may be indicated.
End of document: BNWUUM01
Vibration Safety Switch Adjustments
102
Содержание MWF125J7
Страница 2: ......
Страница 8: ......
Страница 9: ...Installation 1 5 ...
Страница 15: ...Safety Suspended Open Pocket Non tilting Washer Extractors PELLERIN MILNOR CORPORATION End of BIUUUS27 11 ...
Страница 39: ...Service and Maintenance 2 35 ...
Страница 51: ...2 Drive Assemblies 2 1 47 ...
Страница 57: ...Pellerin Milnor Corporation Bearing Assembly 4840F MWF100 MWF125 2 of 6 53 ...
Страница 71: ...2 Suspension 2 2 67 ...
Страница 74: ......
Страница 75: ...2 Door Assemblies 2 3 71 ...
Страница 83: ...2 Water and Steam Assemblies 2 4 79 ...
Страница 92: ......
Страница 93: ...2 Chemical Supply Assemblies 2 5 89 ...
Страница 98: ......
Страница 99: ...2 Pneumatic Assemblies 2 6 95 ...
Страница 103: ...2 Control and Sensing Assemblies 2 7 99 ...
Страница 107: ...Reference 3 103 ...
Страница 108: ......
Страница 109: ...3 Dimensional Drawings 3 1 105 ...
Страница 110: ......
Страница 111: ...107 ...
Страница 112: ...108 ...