Pellerin Milnor Corporation
Figure 2. Detailed views
Legend
A.
Top connection between the shell front and the shell side sheet
B.
Bottom connection between the shell front and the shell side sheet
C.
Connection between the shell rear and the bearing housing
D.
Connection between the Pull-up plate and the Hub (outer bolts)
E.
Connection between the Pull-up plate and the Shaft (inner bolts)
M.
Use thread lock compound Locktite 242. Tighten to 1475 FT. LBS.
N.
Use thread lock compound Locktite 242. Tighten items 14 and 15 to 413 FT. LBS. (4 instances).
P.
Apply silicone to the hub side of the gasket.
Q.
0.25 inches [6.3mm].
R.
Use thread lock compound Locktite 242. Tighten items 16 and 17 to 36 IN. LBS. (18 instances).
S.
Use thread lock compound Locktite 242. Tighten items 20 and 15 to 413 FT. LBS. (4 instances).
T.
Apply oil to the o-rings before you assemble.
Cylinder and Bearing Installation
2 of 3
4840F, MWF100, MWF125
57
Содержание MWF100C7
Страница 2: ......
Страница 8: ......
Страница 9: ...Installation 1 5 ...
Страница 43: ...Service and Maintenance 2 39 ...
Страница 55: ...2 Drive Assemblies 2 1 51 ...
Страница 64: ...Pellerin Milnor Corporation Bearing Assembly 4840F MWF100 MWF125 2 of 6 60 ...
Страница 71: ...2 Suspension Assemblies 2 2 67 ...
Страница 74: ......
Страница 75: ...2 Tilt Assemblies 2 3 71 ...
Страница 80: ......
Страница 81: ...2 Door Assemblies 2 4 77 ...
Страница 89: ...2 Water Steam Drain 2 5 85 ...
Страница 97: ...2 Chemical Supply Assemblies 2 6 93 ...
Страница 102: ......
Страница 103: ...2 Pneumatic Assemblies 2 7 99 ...
Страница 107: ...2 Control and Sensing Assemblies 2 8 103 ...
Страница 109: ...Reference 3 105 ...
Страница 110: ......
Страница 111: ...3 Dimensional Drawings 3 1 107 ...
Страница 112: ......
Страница 113: ...109 ...
Страница 114: ......
Страница 115: ...111 ...
Страница 116: ...112 ...