Pellerin Milnor Corporation
21
3.11.1.1
The Names and Timers Area (A)
BNCLJO07.C02 0000187290 E.3 C.5 F.2 9/11/20 10:29 AM Released
This area displays the running formula’s name and number, the current step number, the total time
in the formula, and the time remaining in the formula and the current step.
Figure 11.
The Names and the Timers Area
Legend
F#..
Formula number
Fn..
Formula name
Fr..
Remaining formula time
Ft..
Total formula time
S#..
Step number
Sr..
Remaining step time
St..
Total step time
3.11.1.2
The Machine Status Area (B)
BNCLJO07.C05 0000187329 E.3 C.5 F.2 9/11/20 10:31 AM Released
This area displays the current and desired water level and temperature for the step in progress, the
current cylinder motion, and the current state of each valve.
Figure 12.
The Machine Status Area
Legend
C...
Chemical signals and chemical
flush valve. Numbers 1–8 indicate
a chemical is being injected. F indi-
cates a chemical flush is occurring.
Cm..
Cylinder motion
Cs..
Cylinder speed, in rotations per mi-
nute. Displays “RS” during Rin-
Save
®
extract deceleration.
D...
Date and time
Dr..
Drain indicators
Lc..
Current level (percentage)
Ld..
Desired level
M...
Current machine status area
P...
Formula progress bar
S...
Steam and cooldown indicators
Sn..
Step name
Tc..
Current temperature
Td..
Desired temperature
W...
Water valve indicators
Содержание MilTouch MWB26Z
Страница 2: ......