PELLERIN MILNOR CORPORATION
BIVSVI01 (Published) Book specs- Dates: 20110301 / 20110301 / 20110301 Lang: ENG01 Applic: VSV
Installation of the Laser Positioner for Traversing Shuttles
NOTICE P1: "Remove power from the machine" means use the necessary safety procedure for
your location. In the USA, this is the OSHA lockout/tagout (LOTO) procedure. More local
requirements can also apply.
Milnor traversing shuttles manufactured after December 2010 are provided with a laser system to
control shuttle travel along the rail (traverse) and the positions at which the shuttle stops. An
older shuttle can be retrofitted with this system if it meets the following criteria:
• The system has, or is upgraded to Dryer/Shuttle controller (Drynet) software version 21010
or later and shuttle software with a matching date code.
• The shuttle has, or is upgraded to the microprocessor board with part number 08BSPE2T
(2004 to current). The 08BSPE1T (circa 2000) and 08BSPET (circa 1994) will not work.
• The shuttle manual controls are housed in a stationary cabinet, not a shuttle-mounted box.
The laser positioner replaces the switches, targets, and mounting hardware previously used for
this purpose. The laser positioner system uses the Banner L-Gage LT7 Laser.
1.
Hardware Installation
WARNING 1 : Strike and Crush Hazards
—A traveling machine such as a shuttle can
strike, crush, or entrap you if you ride on it or enter its path. Traveling machines or their
components can move automatically in any direction. Placing a system machine on line by
energizing the machine control may immediately summon a shuttle or other traveling machine.
• Except where specified in this instruction, remove power from the machine to work in or
near the shuttle path.
The laser beam must be parallel with the axis of shuttle travel. Typically the laser and target are
mounted approximately 7 feet (1.8 meters) above the floor and and horizontally centered on the
shuttle frame, but this can be modified to suit the individual circumstances. The beam must be
unobstructed at all times. Locate the hardware with respect to the shuttle as follows:
Stationary laser support post—in proximity to the stationary shuttle control cabinet.
Reflector—on the shuttle frame. Detailed mounting instructions follow.
Install the hardware as shown in the figures below. It is necessary to install the laser on the
support post but not anchor the post until the laser is aligned with the target.
CAUTION 2 : Risk of Costly Damage
—Until the laser support post is anchored, it can fall
if it or the cable is hit by an object such as a fork lift. This will likely destroy the laser.
• Use care to keep clear of the post except to intentionally reposition it during alignment.
• Route the cable away from any interference and secure it.
32
Содержание COLFM 111
Страница 2: ......
Страница 4: ......
Страница 5: ...Safety Information 1 1 ...
Страница 22: ......
Страница 23: ...Installation 2 19 ...
Страница 48: ......
Страница 49: ...Service and Maintenance 3 45 ...
Страница 88: ......
Страница 89: ...Dimensional Drawings 4 85 ...
Страница 90: ......
Страница 91: ...87 ...
Страница 92: ...88 ...
Страница 93: ...89 ...
Страница 94: ......
Страница 95: ...91 ...
Страница 96: ......
Страница 97: ...93 ...
Страница 98: ...94 ...
Страница 99: ...95 ...
Страница 100: ...96 ...
Страница 101: ...97 ...
Страница 102: ...98 ...
Страница 103: ...99 ...
Страница 104: ...100 ...