Chapter 4. Testing and Troubleshooting
PELLERIN MILNOR CORPORATION
Display or Action
Explanation
from the input status display begins the output test.
Tip:
In the output test, the
coin count
window flashes 00 unless the controller is counting down a
safety delay. During the delay period of up to 100 seconds, the
coin count
window is dark and the
decimal point in the
Machine Status
window flashes to indicate that the controller is working.
When the safety delay time expires, the
Coin Count
window again flashes 00.
normal display immediately upon entering the output test. The
Minutes
Remaining
window displays the number of the selected output or functional
test, and the
Machine Status
window displays the status of the selected item.
0
in the
Machine Status
window indicates that the selected output or functional
test is in the inactive state (off).
1
in the
Machine Status
window indicates that the selected output or functional
test is active (on).
turns off the selected output or functional test if it is on, then advances to the
next output.
toggles the on/off status of the selected output or functional test.
4.2.4.
Functional Tests
In the output testing mode, the controller provides two functional tests. These tests are addressed
in the same manner as the output tests, but also check the status of several inputs by simulating
certain elements of a wash cycle. Functional test 12 (see Section 4.2.4.1) verifies the fill and bath
operations, while functional test 13 (see Section 4.2.4.2) checks the function of the inverter
through all basket speeds.