Chapter 4. Testing and Troubleshooting
PELLERIN MILNOR CORPORATION
Display or Action
Explanation
displays the date code of the software in the machine. This keystroke also
advances the controller beyond the point at which a formula can be started
without inserting coins. If the intent was to start a formula without requiring
coins, turn the
Attendant
switch to the vertical position and return it to the
horizontal position, then immediately press the
Start
button.
The software date code for this example machine is 20001.
from the software date code display, displays the machine inputs status. For
each input made, one segment of the
Minutes Remaining
window illuminates.
Refer to Figure 16 for which segment corresponds to each input.
Tip:
Because the
Select
button advances the control from displaying inputs to testing outputs, it is not
practical to view the status of the
Select
button input on the display. The
Select
button can be
assumed to be working properly if the control advanced from displaying the software date code to
the display inputs test.
4.2.3.
Actuating Outputs and Functional Tests
Table 8: Output Signals
Output Name
Connector
Pins
Function
Test
Door lock
9‚ 10
door locks
00
Drain speed
7‚ 8
inverter drives motor at drain speed;
inverter enabled output also engaged
01
Drain closed
3‚ 4
drain closes
02
Hot water
MTA5
1‚ 2
hot water valve opens
03
Cold water
9‚ 10
cold water valve opens
04
Clockwise wash
7‚ 8
inverter drives motor clockwise at
wash speed; inverter enabled output
also engaged
05
Counter-clockwise
wash
3‚ 4
inverter drives motor counter-
clockwise at wash speed; inverter
enabled output also engaged
06
Extract speed
MTA4
1‚ 2
inverter drives motor at extract speed;
inverter enabled output also engaged
07
Inverter enable
1‚ 2
inverter is enabled for operation
08
Chemical 1
3‚ 4
30-second signal for chemical 1
(detergent)
09
Chemical 2
7‚ 8
30-second signal for chemical 2
(bleach)
10
Chemical 3
MTA6
9‚ 10
30-second signal for chemical 3
(finish)
11
Display or Action
Explanation