15. Output bias adjustment
Set the DMM to measure DC volts, and position the leads of the DMM on TP1 and TP3 as
shown in the photo below. Adjust R18
, the “L Bias” potentiometer, to get a reading of about
11V.
Move the positive lead to TP2,
and adjust R17 (“R Bias”) to get about 11V again.
If you cannot adjust the pot to get to 11V, unplug power and go back and check everything
again.
Note that you can experiment with this setting to change the sound of the amp. There will be
no harm to the amp in setting this wherever you like.