OM-229 930 Page 35
6-7. Remote Voltage/Amperage Control
1
Remote Receptacle RC4
Connect optional remote voltage/
amperage (V/A) control to RC4
(see Section 5-11).
Use receptacle to connect remote
control or wire feeder.
When a remote voltage/amperage
control is connected to the Remote
receptacle, the Auto Sense Re-
mote feature automatically
switches voltage/amperage con-
trol to the remote control (see Sec-
tions 5-11 and 6-3).
With remote voltage/amperage
control connected, weld output in
CC mode is determined by a com-
bination of front panel and remote
control voltage/amperage settings.
In CV mode, weld output is con-
trolled through remote control only.
If no remote voltage/amperage
control is connected to the Remote
receptacle, the front panel Voltage/
Amperage control adjusts voltage
and amperage.
2
Remote Hand Control
(Optional)
3
Remote Foot Control
(Optional)
Engine runs at weld/power
speed in Wire mode whenever
a device connected to the re-
mote receptacle makes clo-
sure between pins A and B. In
all other modes, the engine
runs at idle speed until a load is
applied.
Process = Stick (Using Remote On/Off)
In Example:
2
Max = 160 A CC/DC
Min = 25 A CC/DC
Max (160 A DC)
Min (25 A DC)
Connect Remote
V/A Control To
Remote
Receptacle RC4
Set V/A Control
(Mid-Range: About 160 A)
Adjust Remote V/A Control
(Stick Welding Only)
3
1
Select DC Output
And Polarity
Ref. 804 857-A / Ref. 229 219-A / S-0769 / S-0774
Содержание TRAILBLAZER 302 AIR PAK
Страница 45: ...OM 229 930 Page 41 SECTION 9 GENERATOR ENGINE MAINTENANCE 9 1 Maintenance Label ...
Страница 52: ...OM 229 930 Page 48 10 2 Compressor Maintenance Label ...
Страница 62: ...OM 229 930 Page 58 SECTION 13 ELECTRICAL DIAGRAMS Figure 13 1 Circuit Diagram For Welding Generator ...
Страница 63: ...OM 229 930 Page 59 228 867 F ...