OM-229 930 Page 16
SECTION 4
−
SPECIFICATIONS
4-1. Weld, Power, And Engine Specifications
Welding
Mode
Rated
Welding
Output
Maximum
Open-Circuit
Voltage
Weld
Output Range
Generator
Power Rating
Fuel
Capacity
Engine
CC/DC
280 A, 32 V, 100%
Duty Cycle
50
10
−
300 A
Continuous: 11 kVA/kW,
100/50 A,
120/240 V AC, 60 Hz,
Single-Phase,
Peak: 13 kVA/kW
(w/Weld Contactor Off)
12 gal (45 L)
Tank
Kohler CH-750
Air-Cooled,
Two-Cylinder,
Four-Cycle,
30 HP Gasoline
Engine w/Electronic
Governor
CV/DC
300 A, 32 V, 100%
Duty Cycle
350 A, 32 V, 60%
Duty Cycle
35
13
−
35 V
CC/AC
200 A, 25 V, 60%
Duty Cycle
60
10
−
225 A
4-2. Air Compressor Specifications
Compressor Type
Air Output At 100 psi*
100% Duty Cycle
Pressure
Safety Relief
Valve Setting
Air Compressor
Oil Capacity*
Rotary Screw
26 scfm @ 3600 RPM
21 scfm @ 3000 RPM
17 scfm 2400 RPM
*100 psi = 689 kPa
Range: 80
−
150 psi
(552
−
1034 kPa)
Auto Shutoff: 165 psi
(1138 kPa)
Pressure Relief: 200 psi
(1379 kPa)
1.75 qt (1.7 L)
* Use Only Mobil 1
Synthetic ATF Oil Or
Compressor May Be
Damaged
4-3. Sound Level Table
−
7 Meter (23 Ft) (Reference SAE J2101)
Idle Speed
2400 RPM
Weld Speed
3000 RPM
3600 RPM
Air Compressor On
73.5 dB
76.4 dB
81.6 dB
Air Compressor Off
70.9 dB
N/A
77.7 dB
Weld Load
N/A
76.4 dB
81.6 dB
Содержание TRAILBLAZER 302 AIR PAK
Страница 45: ...OM 229 930 Page 41 SECTION 9 GENERATOR ENGINE MAINTENANCE 9 1 Maintenance Label ...
Страница 52: ...OM 229 930 Page 48 10 2 Compressor Maintenance Label ...
Страница 62: ...OM 229 930 Page 58 SECTION 13 ELECTRICAL DIAGRAMS Figure 13 1 Circuit Diagram For Welding Generator ...
Страница 63: ...OM 229 930 Page 59 228 867 F ...