A complete Parts List is available at www.MillerWelds.com
OM-4426 Page 18
Ref. 220 807
−
B
The AC generator power curve
shows the generator power avail-
able in amperes at the receptacles.
Tools and motors are designed to
operate within 10% of 120/240
VAC.
4-5. Generator Power Curve
0
50
100
150
200
250
300
0
10
20
30
40
50
60
70
80
90
100
AC AMPERES AT 240 V
AC VOL
TS
+/
−
10%
EFI Engine
Carb Engine
0
20
40
60
80
100
120
140
160
180
200
AC AMPERES AT 120 V
0
25
50
75
100
125
150
Duty cycle is the percentage of 10
minutes that unit can weld at rated
load without overheating.
NOTICE
−
Exceeding duty cycle
can damage unit and void warranty.
AC output is not available on all
models.
100% Duty Cycle at 280 Amperes DC
Continuous Welding
4-6. Duty Cycle