OM-485 Page 19
SECTION 6 – OPERATING AUXILIARY EQUIPMENT
6-1.
Auxiliary Power Receptacles And Circuit Breakers
Use GFCI-protected exten-
sion cords.
1
120 V 15 A AC Duplex
Receptacle RC1
2
240 V 15 A AC Duplex
Receptacle RC2
RC1 and RC2 supply 60 Hz single-
phase power at weld/power speed.
Maximum output from RC1 is 3.6
kVA/kW. Maximum output from
RC2 is 4.0 kVA/kW.
3
Circuit Breakers CB3 And
CB4
CB3 and CB4 protect RC1 from
overload. If CB3 or CB4 opens, half
of RC1 does not work. Press button
to reset breaker.
4
Circuit Breaker CB5 And CB6
CB5 and CB6 protect RC2 from
overload. If CB5 or CB6 opens,
RC2 does not work. 120 volts may
still be present at RC2.
If a circuit breaker continues to
open, contact Factory
Authorized Service Agent.
Combined output of all receptacles
limited to 4 kVA/kW output of the
generator.
EXAMPLE: If 15 A is drawn from
RC1, only 9 A is available at RC2:
(120 V x 15 A) + (240 V x 9 A) = 4.0
kVA/kW
5
Auxiliary Power While
Welding Label
Ref. ST-180 601-F
1
5
S-135 048-B
See Owner’s Manual for additional information.
Weld Current
CV/CC
Watts
Current In
Amperes
120V
250
225
200
150
100
50
0
2200
2750
3250
3300
3800
4000
4000
23
27
27.5
32
33.3
33.3
18.5
SIMULTANEOUS WELDING AND POWER
240V
11.5
13.5
14
16
16.7
16.7
9
3
2
4